Installation Procedure - Carrier 42NQV050M Service Manual

Split type indoor and outdoor unit
Hide thumbs Also See for 42NQV050M:
Table of Contents

Advertisement

10-1. Installation Diagram of Indoor and Outdoor Units
...
Super Oxi Deo filter
Super Sterilizer filter
ƒ
Batteries
Wireless remote control
When installing the outdoor unit, leave
open in at least two of direction (A),
(B), (C) and (D) shown in the Þ gure on
the right.
Before installing the wireless remote controller
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (− ) positions.

10. INSTALLATION PROCEDURE

ˆ
Pan head
wood screw
Vinyl tape
Apply after carrying
out a drainage test.
80 mm or more only
when unobstructed
to the front and both
sides.
(C)
(B)
2 Wireless remote controller
Installation
Hook
plate
Shield pipe
Remote control holder
(D)
Saddle
Extension
drain hose
(Not available,
provided by installer)
(A)
3 Batteries
– 45 –
For the rear left and left piping
Wall
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain hose sloped
downward.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Bottom
Rear
left
right
Bottom left
Insulate the refrigerant pipes separately
with insulation, not together.
8 mm thick heat resisting
polyethylene foam
Left