Rheem RP1336AC1NA Installation Instructions Manual page 14

Hide thumbs Also See for RP1336AC1NA:
Table of Contents

Advertisement

INSTALLATION
Interconnecting Tubing (cont�)
Example: A 3-Ton heat pump unit is installed 50'
below the ID unit, requires a 75' of 1/2" diameter
liquid line, and 4 90° LR elbows�
• Fitting Equivalent Length (ft.) = 4 x .9 = 3.6'
• Total Equivalent Length (ft.) = 75' + 3.6' = 78.6'
• Rounded-down value (ft.) = 75'
Liquid Line
R-410A
Size
Liquid Line
System
Connection
Size (Inch
Capacity
Size (Inch
O.D.) [mm]
Model
I.D.) [mm]
1/4 [6.35]
5/16 [7.94]
3/8 [9.53]
37
3/8" [9.53]
7/16 [11.12]
1/2 [12.71]
(Exerpt from Table 2, page 17)
Long Line Set Applications
Long line set applications are defined as applica-
tions that require accessories or alternate construc-
tion methods� The following are special consider-
ations that need to be addressed when installing a
long line set application:
• Additional refrigerant charge
• Fitting losses and maximum equivalent length
considerations
• Refrigerant migration during the off cycle
• Oil return to the compressor
• Capacity losses
• System oil level adjustment
Table 2 is used to determine if the application is
considered to have a long line set� The region of
the chart that is shaded grey is considered to be
a long line set application.
Oil Level Adjustments for Long
Line Set Applications
Additional oil will need to be added for long line set
applications� (Ref� Table 2)� Below is the equation for
the oil level adjustment and the compressor name
plate oil charge for the different od units.
Oil to be Added = [(Charge Adjustment + OD
Unit Name Plate Charge (oz.)) x (0.022) – [(0.10) x
(Compressor Name Plate Oil Charge (oz.))]
Example: An application requires 125ft of line set
with a liquid line diameter of 3/8", Charge Adjust-
ment = 52.4 oz., Name Plate Charge = 107 oz.,
Name Plate Oil Charge = 25 oz., Oil to be Added =
((52.4 oz. +107 oz.) x .022) – (.10 x 25 oz.) = 1.0 oz.
14
25 [7.62]
50 [15.24]
75 [22.86]
100 [30.48]
25 [7.62]
N/R
N/R
N/R
25 [7.62]
50 [15.24]
60 [18.29]
45 [13.72]
25 [7.62]
50 [15.24]
75 [22.86]
80 [24.38]
25 [7.62]
50 [15.24]
75 [22.86]
95 [28.96]
25 [7.62]
50 [15.24]
75 [22.86]
95 [28.96]
This application is acceptable because the 50'
vertical rise is less than the maximum rise of 75' for
this application� The application is also considered
to have a long line set� Reference the long line set
section of the I&O for detail�
Liquid Line Size
Elevation (Above or Below) Indoor Coil
Total Equivalent Length - Feet [m]
125 [45.72]
150 [45.72]
175 [53.34]
200 [60.96]
Maximum Vertical Separation - Feet [m]
N/R
N/R
N/R
N/R
35 [10.67]
20 [6.1]
5 [1.52]
N/R
80 [24.38]
75 [22.86]
70 [21.34]
65 [19.81]
90 [27.43]
90 [27.43]
85 [25.91]
85 [25.91]
95 [28.96]
95 [28.96]
95 [28.96]
95 [28.96]
Compressor
OD Model
ZP31K5E-TF5-13R
RP1336AC
ZP36K5E-TF5-13R
RP1342AC
ZP42K5E-TF5-13R
RP1348AC
ZP49K6E-TF5-130
RP1360AC
ZP31K5E-TFD-13R
RP1336AD
ZP36K5E-TFD-13R
RP1342AD
ZP42K5E-TFD-13R
RP1348AD
ZP49K6E-TFD-130
RP1360AD
Compressor
OD Model
ZP31K5E-TF5-13R
RP1436AC
ZP36K5E-TF5-13R
RP1442AC
ZP42K5E-TF5-13R
RP1448AC
ZP49K6E-TF5-130
RP1460AC
ZP31K5E-TFD-13R
RP1436AD
ZP36K5E-TFD-13R
RP1442AD
ZP42K5E-TFD-13R
RP1448AD
ZP49K6E-TFD-130
RP1460AD
OD Model
Compressor
ZP16K5E-PFV-13R
RP1418AJ
ZP21K6E-PFV-130
RP1442AJ
ZP25K5E-PFV-13R
RP1430AJ
ZP31K5E-PFV-13R
RP1436AJ
ZP36K5E-PFV-13R
RP1442AJ
ZP42K5E-PFV-13R
RP1448AJ
ZP49K6E-PFV-130
RP1460AJ
225 [68.58]
250 [76.20]
275 [83.82]
300 [91.44]
N/R
N/R
N/R
N/R
N/R
N/R
N/R
N/R
60 [18.29]
55 [16.76]
50 [15.24]
45 [13.72]
85 [25.91]
80 [24.38]
80 [24.38]
80 [24.38]
95 [28.96]
90 [27.43]
90 [27.43]
90 [27.43]
Name Plate Oil
Charge (oz)
42
42
42
42
42
42
42
42
Name Plate Oil
Charge (oz)
42
42
42
42
42
42
42
42
Name Plate Oil
Charge (oz)
21
21
25
21
42
42
42