• Connecting the Drain Hose
See 4. Connecting the Drain Hose
Indoor unit installation
• Secure using 6 screws for floor installations. (Do not forget to secure to the rear wall.)
• For wall installations, secure the mounting plate
• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1. Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring points
on the wall.
2. Secure the mounting plate to the wall with screws.
3. Once refrigerant piping and drain piping connections are complete, fill in the gap of the through hole with putty.
A gap can lead to condensation on the refrigerant pipe, and drain pipe, and the entry of insects into the pipes
4. Attach the front panel and front grille in their original positions once all connections are complete.
11.3.3.2. Half concealed installation
• Only item peculiar to this installation method are given here. See Exposed installation for additional instructions.
Wall hole
• Drill a wall hole of the size shown in the illustration on the
right.
using 5 screws and the indoor unit using 4 screws.