Error Codes Table - Panasonic CS-E9GFEW Service Manual

Hide thumbs Also See for CS-E9GFEW:
Table of Contents

Advertisement

10.2. Error Codes Table

Diagnosis
Abnormality / Protection control
display
H11
Indoor / outdoor abnormal
communication
H12
Indoor unit capacity unmatched
H14
Indoor intake air temperature sensor
abnormality
H15
Outdoor compressor temperature sensor
abnormality
H16
Outdoor Current Transformer open
circuit
H19
Indoor fan motor merchanism lock
H23
Indoor heat exchanger temperature
sensor abnormality
H27
Outdoor air temperature sensor
abnormality
H28
Outdoor heat exchanger temperature
sensor abnormality
H30
Outdoor discharge temperature sensor
abnormality
H32
Outdoor discharge temperature sensor 2
abnormality
H33
Indoor/Outdoor wrong connection
H34
Outdoor heatsink temperature sensor at
Control Board
H36
Outdoor gas pipe temperature sensor
abnormality
H37
Outdoor liquid temperature sensor
abnormality
H38
Indoor/Outdoor mismatch (brand code)
H39
Abnormal indoor operating unit or
standby units
H41
Abnormal wiring or piping connection
H97
Outdoor Fan Motor lock abnormality
H98
Indoor high pressure protection
H99
Indoor heat exchanger anti-freezing
protection
F11
Cooling / Heating cycle changeover
abnormality
F17
Indoor standby units freezing
F90
PFC control
Abnormality
Emergency
Judgement
operation
> 1 min after starting
Indoor fan
operation
operation only
(single type only)
Continue for 5 sec.
Continue for 5 sec.
Continue for 5 sec.
(Single type only)
Continue for 5 sec.
(Single type only)
Continue for 5 sec.
Continue for 5 sec.
Continue for 2 sec.
Continue for 2 sec.
Continue for 2 sec.
4 times occurance
within 30 minutes
54
Primary location to verify
• Internal / external cable
connections
• Indoor / Outdoor PCB
• Indoor units total capacity
• Intake air temperature
sensor (defective or
disconnected)
• Compressor temperature
sensor (defective or
disconnected)
• Decreased amount of
refrigerant
• Outdoor PCB
• Fan motor
• Indoor PCB
• Heat exchanger temperature
sensor (defective or
disconnected)
O
• Outdoor temperature sensor
(defective or disconnected)
O
• Outdoor heat exchanger
temperature sensor
(defective or disconnected)
• Outdoor discharge
temperature sensor
(defective or disconnected)
• Outdoor discharge
temperature sensor 2
(defective or disconnected)
• Indoor/Outdoor supply
voltage
• Outdoor heatsink
temperature sensor at
Control Board (defective or
disconnected)
• Outdoor gas pipe
temperature sensor
(defective or disconnected)
• Outdoor liquid temperature
sensor (defective or
disconnected)
• Piping connection error
• Indoor/Outdoor cable
connection error
• Wiring or piping connection
• Outdoor Fan Motor
• Air filter dirty
• Air circulation short circuit
• Insufficient refrigerant
• Air filter dirty
• 4-way valve
• V-coil
• Outdoor expansion valve
leakage
• Indoor unit pipe temperature
sensor
• Outdoor PCB
• Outdoor Fan Motor
Note
Multi type
only
Single
type only
Multi type
only
Multi type
only
Multi type
only
Multi type
only
Multi type
only
CU-
2E15GBE
Multi type
only