OPERATING PROCEDURE
4. Removing the defrost thermistor, discharge temper-
ature thermistor and outdoor heat exchanger tem -
perature thermistor
(1) Remove the top panel, cabinet and service panel.
(Refer to 1.)
(2) Remove the back panel. (Refer to 1.)
(3) Remove the inverter assembly. (Refer to 2.)
(4) Pull out the defrost thermistor from its holder. (Photo 6)
(5) Pull out the discharge temperature thermistor from its
holder. (Photo 5)
(6) Pull out the outdoor heat exchanger temperature thermistor
from its holder. (Photo 6)
5. Removing outdoor fan motor
(1) Remove the top panel, cabinet and service panel.
(Refer to 1.)
(2) Remove the back panel. (Refer to 1.)
(3) Remove the inverter assembly. (Refer to 2.)
(4) Remove the propeller.
(5) Remove the screws fixing the fan motor.
(6) Remove the fan motor.
Photo 5
Discharge temperature thermistor
Photo 6
Outdoor heat
exchanger
temperature
thermistor
Photo 7
Screws of the outdoor fan motor
Propeller
46
PHOTOS
Defrost
thermistor