3
Dimensional drawings
FHY35∼45GZ7V1
Slit hole position for rear piping connection
(from the front)
1 Air discharge grille
2 Air suction grille
3 Air filter
4 Gas pipe connection φA Flare connection
5 Liquid pipe connection J6.35 Flare connection
6 Drain pipe connection V.P.20
7 Grounding terminal M4
8 Suspension bracket
9 Rear piping connection hole - slit hole
10 Upper refrigerant piping connection hole - slit hole
11 Right side piping connection hole - slit hole
12 Rear left side drain piping connection hole - slit hole
13 Left side drain piping connection hole - slit hole
14 Right side drain piping connection hole - slit hole
15 Power supply / control wiring connection (upper)
16 Power supply / control wiring connection (rear)
17 Remote control code connection (upper)
18 Remote control code connection (rear)
19 Rear piping connection hole - slit hole J100
FH35BZV1
FHYP35∼45BV1
Obstacle
Note:
1. Location of unit's name plate: bottom of fan housing inside the
suction grille.
2. In case of using infrared remote control, this position will be a signal
receiver. Refer to the drawing of infrared remote control in detail.
3. The remote control code is the standard (about 3m outside the
machine) attached.
2
x 2 Wicks x O.D. J5.4)
(0.5 mm
(It is not attached in VRV.)
• Ceiling Suspended Unit • R-407C • FH(Y)-GZ/BZ/FHYP-B
Drain outlet V.P.20
(for left piping)
Suspension bolt
60 mm or more
Service space
Notes:
1. Name plate: sticked on the bottom part of fan housing in suction grille
2. When using a remote controller, this position will be a signal receiver. Refer to the detailed
drawing of the remote controller
3. The standard length of remote control cord is approximately 3m.
(0.5mm x 2 cores x J5.4 0.D.)
Hanging bolt
(Hanging position)
30 or more
(Service space)
View from the front
Floor side
Drain pipe connection
VP20
(For left piping)
• Split - Sky Air • Indoor Units
DAIKIN name plate
(See note 2)
60 mm or more
Service space
(Suspension position)
Position slit hole for taking out in piping back
(View from the front)
30 or more
(Service space)
Brand name plate
1
Air discharge grille
(Note 2)
2
Air suction grille
3
Air filter
Gas pipe connection J12.7 flare
4
Liquid pipe connection J6.4 flare
5
6
Drain pipe connection VP20
7
Earth terminal (inside the electric components box) M4
8
Suspension bracket
9
Backward piping and wiring connection opening lid
10
Upward piping and wiring connection opening lid
11
Right side pipe connection - slit hole
12
Left back drain pipe connection - slit hole
13
Right side drain pipe connection - slit hole
14
Right side drain piping connection hole- slit hole
Hole of wall for taking out in piping back J100
15
Upward drain pipe connection J60
16
Upward gas pipe connection J36
17
Upward liquid pipe connection J26
18
unit (mm)
Model
A
FH35GZ
12.70
FHY35GZ
FH45GZ
15.90
FHY45GZ
Wall hole position for rear
piping connection
(from the front)
3TW20524-1A
Position: hole of wall for taking out in piping back
(View from the front)
3D027536A
10
3
9