BATTERY TEST
Ranges: 1.5 V, 9 V
Accuracy: ± (3.5 % rdg + 2 dgts)
OVERLOAD PROTECTION
Voltage, Resistance, Diode, Continuity:
1000 VDC or 750 VAC rms
200 mV Range: 1000 VDC / 750 VAC rms (3 minutes)
Current: 0.315 A / 1000 V fast blow ceramic fuse 6.3 × 32 mm
mA JACK: Input warning detects wrong switch/input jack
configuration
AUXILIARY FEATURES
DATA HOLD: Freeze the latest reading on the display.
MIN/MAX: Record the maximum and minimum reading in a
measurement.
15XP-B Electrical Specifications
(at 23°C ± 5°C, < 75 % R.H.)
DC VOLTS
Ranges: 200 mV, 2 V, 20 V, 200 V, 1000 V
Accuracy: ±(0.5 % rdg + 1 dgt)
AC VOLTS (45 Hz to 500 Hz)
Ranges: 200 mV, 2 V, 20 V, 200 V, 750 V
Accuracy: ±(1.5 % rdg + 5 dgts) 45 Hz to 100 Hz on 200 mV
range: ±(1.5 % rdg + 5 dgts) on 2 V to 750 V ranges
DC CURRENT
Ranges: 200 µA, 2000 µA, 20 mA, 200 mA, 2 A
Accuracy: ±(1.0 % rdg + 2 dgts) on 200 µA to 200 mA ranges:
±(2.0 % rdg + 3 dgts) on 2 A range
AC CURRENT (45 Hz to 500 Hz)
Ranges: 200 µA, 2000 µA, 20 mA, 200 mA, 2 A
Accuracy: ±(1.5 % rdg + 5 dgts) on 200 µA to 200 mA ranges:
±(2.5 % rdg + 5 dgts) on 2 A range
RESISTANCE
Ranges: 200 , 2 k, 20 k, 200 k, 2 M, 20 M, 2000 M
15