Connecting The Piping - LG AS-W096E1G0 Engineering Product Data Book

Hide thumbs Also See for AS-W096E1G0:
Table of Contents

Advertisement

14. Installation

Connecting the Piping

Indoor
1. Prepare the indoor unit's piping and drain hose for
installation through the wall.
2. Pull the plastic tubing cover(see the illustration by)
and pull the tubing and drain hose away from
chassis.
For right rear piping
1. Route the indoor tubing and the drain hose in the
direction of rear right.
2. Insert the connecting cable into the indoor unit from the
outdoor unit through the piping hole.
• Do not connect the cable to the indoor unit.
• Make a small loop with the cable for easy
connection later.
3. Tape the tubing, drain hose, and the connecting
cable. Be sure that the drain hose is located at the
lowest side of the bundle. Locating at the uper side
can cause drain pan to overflow inside the unit.
If the drain hose is routed inside the room, insulate the
hose with an insulation material* so that dripping from
"sweating"(condensation) will not damage furniture or
floors.
*Foamed polyethylene or equivalent is recommended.
4. Indoor unit installation
Hook the indoor unit onto the upper portion of the
installation plate.(Engage the hooks of the rear top of
the indoor unit with the upper edge of the installation
plate.) Ensure that the hooks are properly seated on
the installation plate by moving it left and right.
Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots(clicking sound).
2
1
Drain hose
Tape
Connecting
pipe
Drain hose
Connecting cable
Connecting
cable
Drain hose
2008 Product Data
95

Hide quick links:

Advertisement

Table of Contents
loading