Checking The Drainage - LG AS-W096E1G0 Engineering Product Data Book

Hide thumbs Also See for AS-W096E1G0:
Table of Contents

Advertisement

14. Installation

Checking the Drainage

To check the drainage.
1. Pour a glass of water on the evaporator.
2. Ensure the water flows through the drain hose of the
indoor unit without any leakage and goes out the
drain exit.
Drain piping
1. The drain hose should point downward for easy drain
flow.
2. Do not make drain piping like the following.
Do not raise
Water
leakage
102
2008 Product Data
Accumulated
drain water
Air
Water
Waving
leakage
Tip of drain hose
dipped in water
Water
leakage
Ditch
Connecting area
drain hose
Leakage
checking
Downward slope
Less than
50mm gap