3. Features & Benefits

Auto Changeover

With heat pump model,cooling and heating operation is
changed automatically on the base of setting temp.
• Initial Setting Temp:18˚C Memorize final setting temp.
Hot Start Function
During starting of the unit in the heating mode it prevents
cold air blowing from the unit. It starts the indoor fan only
after indoor unit pipe temperature reaches a preset value
(28˚C).
When indoor unit pipe temperature reaches 28˚C, then
for initial 1 minute the indoor fan runs at a low speed
and after that at the setting speed.
Low Ambient
Cools the room as is necessary, even in winter.
- In case you hold a party indoors in winter, you need
to operate equipment in the computer server room
for long hours, or you cannot open windows for the
security's sake, you can cool the room using the
Inverter air conditioner.
Under such circumstances, ordinary conventional air
conditioners may have heat exchangers in indoor
equipment frozen, thus not properly functioning to
cool the room. However, in the case of inverter air
conditioners, you can adjust the speed of
compressors and outdoor equipment's fans to
prevent heat exchangers in indoor equipment from
being frozen, thus cooling the room more easily.

Auto Restart Function

In case of a sudden power failure, It automatically sets
the A/C to settings before the power failure when
power returns.
Sleep Mode Auto Control
With one touch of the Sleep mode button,
it automatically programs the Air Conditioning Unit to
turn off, controls the fan speed and adjusts the set
temperature for a more comfortable sleep.
2008 Product Data