1-1-2.

Preparations

Note 1: For details of how remove the cabinet and boards, refer to "2.
DISASSEMBLY".
Note 2: When performing only the adjustments, the lens block and boards
need not be disassembled.
1) Connect the equipment for adjustments according to Fig. 5-1-
5.
2) Connect the adjustment remote commander to the following
connector or jack.
• CN803 of FC-72 board via CPC-12 jig (J-6082-436-A)
• LANC jack (MVC-FD90 model only)
Note 3: As disconnecting the FC-72 board CN801 means disconnecting
the lithium 3V power supply (PK-52/50 board BT701), data such
as date, time will be lost. After completing adjustments, preset
these data.
Note 4: Setting the "Forced Power ON Mode (Forced STILL Mode)"
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the power (STILL mode) to be
turned on with PK-52/50 board removed. After completing
adjustments, be sure to exit the "Forced Power ON Mode".
Note 5: Setting the "Forced Power ON Mode (Forced PLAY Mode)"
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the power (PLAY mode) to be
turned on. After completing adjustments, be sure to exit the "Forced
Power ON Mode".
Note 6: Setting the "Forced Power ON Mode (Forced MOVIE Mode)"
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 03, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the power (MOVIE mode) to be
turned on. After completing adjustments, be sure to exit the "Forced
Power ON Mode".
Note 7: Exiting the "Forced Power ON Mode"
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
Pattern box
Front of the Protection glass
FC-72 board
CN803
5-4
About 90 cm
Fig. 5-1-2.
CPC lid
Screw driver (–)
CPC-12 jig
22 pin flexible board
Insulator side
Fig. 5-1-3.