Multitech BL-Series User Manual page 113

Intelligent data/fax modem
Table of Contents

Advertisement

Switch #11
"AT" Responses/Multi-Tech Responses
(Asynchronous Mode/Leased line/Dial-Up)
In Asynchronous mode, you can set the modem to respond with Result Codes according to the
"Multi-Tech" command response set (Switch #11 in the DOWN position), or to "AT" command
response set (Switch #11 in the UP position). The &Q command performs the same function
(choosing AT or Multi-Tech Result Codes), and is explained further in
"AT" Responses (&Q1)
"Multi-Tech" Responses (&Q0 =
Factory Default Setting
Switch #11
Internal/External Clocking
(Synchronous Mode/Leased Line/Dial-Up)
In Synchronous mode, the transmit clock can be supplied by the DTE on pin 24 of the RS-232C/V.24
interface by placing DIP-Switch #11 UP. Place DIP-Switch #11 in the DOWN position to enable DCE
to control clocking (internal clock via pins 15 and 17 of the RS-232/V.24 interface).
External Clock (pin 24)
Internal Clock (pins 15/17)
Factory Default Setting
Switch #12
Asynchronous/Synchronous Operation -- "Sync"
(Asynchronous/Synchronous Mode/Leased Line/Dial-Up)
The modem can operate in either Asynchronous mode or Synchronous mode. In Synchronous mode,
start and stop bits are eliminated. The modem's internal clock circuits on the RS-232C/V.24 pins 15
and 17 are activated. The modem's Command mode is not accessible in Synchronous mode. This
switch is a means to alternate and to access either mode. In Synchronous mode, you may want to
set the RTS forcing and CTS forcing DIP-Switches so that both of signals act normally (not forced
on).
Synchronous Operation
Asynchronous Operation
Factory Default Setting
Switches #13 and #14
Speed Switches
(Synchronous Mode/Leased Line)
DIP-Switches #13 and #14 are used to set the modem's data transmission rate. Switches #13 and
#14 are used in combination, typically in leased-line and call origination applications.
Note: The modem baud rate command ($MBn) overrides the setting of these speed selection
switches (DIP switches #13 and #14).
2834 Series:
28800 bps Operation
=
19200 bps Operation
=
14400 bps Operation
=
9600 bps Operation
=
Factory Default Setting =
=
Switch #11 UP
Switch #11 DOWN
=
DOWN
=
Switch #11 UP
=
Switch #11 DOWN
=
DOWN
=
Switch #12 UP
=
Switch #12 DOWN
=
DOWN
Switch #13 UP and Switch #14 UP
Switch #13 DN and Switch #14 UP
Switch #13 UP and Switch #14 DN
Switch #13 DN and Switch #14 DN
Switch #13 UP and Switch #14 UP
Chapter 9 - DIP-Switch Settings
Section 5.3
of this manual.
113

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multimodem ii bl-series

Table of Contents