8. COMPRESSOR CONTROL
(1). OPEARTION FREQUENCY RANGE
The operation frequency of the compressor is different based on the operation mode as
shown in the table 9.
(Table 9 : Compressor Operation Frequency Range)
ASYA24LCC
ASYA30LCC
(2). OPEARTION FREQUENCY CONTROL AT START UP
The compressor frequency soon after the start-up is controlled as shown in the figure 10.
(Fig.10 : Compressor Control at Start-up
ASYA24LCC
Frequency
(Frequency)
ASYA24LCC
ASYA30LCC
(Time)
ASYA24LCC
ASYA30LCC
Cooling
Min
Max
15Hz
115Hz
21Hz
94Hz
Time
Frequency
Frequency
40Hz
-
40Hz
59Hz
Time
Time
-
500sec
60sec
40sec
Heating
Min
Max
15Hz
130Hz
21Hz
120Hz
)
ASYA30LCC
Frequency
Frequency
05-10
Dry
34Hz
39Hz
Time
Time