Louver Control - Fujitsu ASYA24LCC Service Instructions Manual

Hide thumbs Also See for ASYA24LCC:
Table of Contents

Advertisement

7. LOUVER CONTROL

(1). LOUVER CONTROL
When the indoor control interface device receives a control signal light from the remote control,
it will actuate, the step motor according to the control signal, and set the louver to each position.
In addition, if the air conditioner is stopped, vertical louver will be closed automatically.
Vertical Air Direction Adjustment
(Function Range)
Each time the button is pressed, the air direction range will change as follow:
(Operation Range)
Cooling / Dry mode
Heating mode
Fan mode
Use the air direction adjustments within the ranges shown above.
Horizontal Air Direction Adjustment
(Function Range)
Each time the button is pressed, the air direction range will change as follow:
The vertical airflow direction is set automatically as shown, in accordance with the type of operation
selected.
Cooling / Dry mode
Heating mode
When the temperature of the air being blown out is low at the start of heating operation or during
defrosting, the airflow direction temporarily becomes
During use of the Cooling and Dry modes, do not set the Air Flow Direction Louver in the Heating
range (
) for long period of time, since water vapor many condense near the outlet louvers and
4
6
drop of water may drip from the air conditioner. During the Cooling and Dry modes, if the Air Flow
Direction Louvers are left in the hating range for more than 20minutes, they will automatically
return to position
During Monitor operation in AUTO CHANGEOVER mode, the airflow direction automatically
becomes
, the horizontal airflow direction does not cahnge, and it cannot be adjusted.
Horizontal flow
Downward flow
.
(Fig 9: Air Direction Range)
1
6
to prevent cold air being blown onto the body.
6
05-08
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aoyr30lctAsya30lccAoyr24lcc

Table of Contents