5. INDOOR FAN CONTROL
(1).Fan speed
( Table 5 : Indoor Fan Speed )
Operation mode
Heating
Cooling
Fan
Dry
Operation mode
Heating
Cooling
Fan
Dry
(2).FAN OPERATION
The airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH, while the indoor
fan only runs.
When Fan mode is set at (Auto), it operates on (MED) Fan Speed.
(3).COOLING OPERATION
Switch the airflow [AUTO], and the
indoor fan motor will run according
to a room temperature, as shown in
Figure 6.
On the other hand, if switched in
[HIGH]
[QUIET], the indoor motor
will run at a constant airflow of [COOL]
operation modes QUIET, LOW, MED,
HIGH, as shown in Table 5.
ASYA24LCC
Air flow mode
Speed (rpm)
Hi
1,310
Me+
1,220
Me
1,120
Lo
940
Quiet
830
Cool air
650
prevention
S-Lo
250
Hi
1,310
Me
1,120
Lo
940
Quiet
830
830
ASYA30LCC
Air flow mode
Speed (rpm)
Hi
1,330
Me+
1,220
Me
1,120
Lo
940
Quiet
830
Cool air
650
prevention
S-Lo
250
Hi
1,330
Me
1,120
Lo
940
Quiet
830
830
(Fig.6)
airflow change - over ( Cooling:AUTO )
HIGH mode
+2.0 C
MED mode
+1.0 C
LOW mode
When the room
temperature lowers
(Room temperature) D (Setting temperature)
05-05
When the room
temperature rises
+2.5 C
+1.5 C