Thermo Pride CMA3-50D36N Installation And Service Manual page 21

Gas fired high efficiency furnace
Hide thumbs Also See for CMA3-50D36N:
Table of Contents

Advertisement

CMA3 SERIES
CMC1 SERIES
Figure 5.
Do not obstruct any return air openings, including the return
:
grille on the furnace. To do so may cause the furnace to activate the high
limit and shut down.
3. The cross-sectional area of the return system leading into the closet (when
located in the floor or ceiling) shall not be less than 250 square inches.
4. The total free area of openings in the floor or ceiling registers serving the
return duct system must be at least 350 square inches. At least one register must
be located where it is not likely to be covered by carpeting, boxes, furniture or
other objects.
5. Materials located in the return duct system must have a flame spread
classification of 200 or less.
6. Non-combustible pans having one inch upturned flanges are to be located
beneath openings in a floor return duct system.
7. Wiring materials located in the return duct system must conform to articles
300-22 of the National Electrical Code NFPA70 (Latest Edition).
18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents