Connecting To Gas Supply - Comfort Glow CF26NR Owner's Operation And Installation Manual

Vent-free natural gas bay front fireplace
Table of Contents

Advertisement

VENT-FREE NATURAL GAS BAY FRONT FIREPLACE
INSTALLATION
Continued
CONNECTING TO GAS
SUPPLY
WARNING: A qualified ser-
vice person must connect fire-
place to gas supply. Follow all
local codes.
WARNING: Never connect
fireplace to private (non-utility)
gas wells. This gas is commonly
known as wellhead gas.
IMPORTANT: Check gas line pressure
before connecting fireplace to gas line. Gas
line pressure must be no greater than 14
inches of water. If gas line pressure is higher,
fireplace regulator damage could occur.
CAUTION : Use only new,
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of 1/2"
or greater
diameter to allow
proper gas volume to fireplace. If
pipe is too small, undue loss of
pressure will occur.
CF26NR
Installation must include a manual shutoff
valve, union, and plugged 1/8" NPT tap.
Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from
fireplace (see Figure 20).
Apply pipe joint sealant lightly to male
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.
CAUTION: Use pipe joint seal-
ant that is resistant to liquid pe-
troleum (LP) gas.
Gas
Control
Approved Flexible
Gas Hose
Figure 20 - Gas Connection
* Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See
Accessories, page 28.
** Minimum inlet pressure for purpose of input adjustment.
12
Install sediment trap in supply line as shown
in Figure 20. Locate sediment trap where it
is within reach for cleaning. Locate sedi-
ment trap where trapped matter is not likely
to freeze. A sediment trap traps moisture
and contaminants. This keeps them from
going into fireplace controls. If sediment
trap is not installed or is installed wrong,
fireplace may not run properly.
A.G.A. Design-Certified
Manual Shutoff Valve With
1/8" NPT Tap*
3" Minimum
Cap
Pipe
Nipple Joint
Sediment Trap
From Gas Meter
(5" W.C.** to
10.5" W.C.
Pressure)
Tee
105443

Advertisement

Table of Contents
loading

Table of Contents