Minimum Framing Dimensions - Napoleon BGD36CFNTR Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

6.2

MINIMUM FRAMING DIMENSIONS

FOR TOP EXIT APPLICATIONS: DO NOT BUILD INTO THIS AREA. IT MUST BE LEFT CLEAR TO
PROVIDE ADEQUATE CLEARANCE FOR THE VENT. IN THIS 14" (356MM) WIDE AREA CENTRED
ALONG THE FRONT OF THE APPLIANCE, NO COMBUSTIBLES ARE ALLOWED.
49"
1245mm
(TOP EXIT)
40 1/2"
1029mm
(REAR EXIT)
Combustion protrusions such as mantels and shelves may occur at or after a minimum distance of 2" (51mm)
away from the side of the appliance. Thereafter, the depth of any protrusions must be equal to or less than the
distance from the side of the appliance up to a depth of 6" (152mm), after which no greater clearance than 6"
(152mm) is required. This can be considered a side wall with no length boundary.
WARNING
!
1 1/2"
38mm
MAX
14"
356mm
MIN
REQUIRED (SUPPLIED)
1 1/2"
38mm
MAX
17 1/4"
438mm
38 3/4"
984mm
40 1/2"
1028mm
STEEL HEADER
35
EN
W415-1345 / B / 10.22.15