Safety • Installation
Electrically powered sump pumps normally give many
years of trouble-free service when correctly installed,
maintained, and used. However, unusual circumstances
(interruption of power to the pump, dirt/debris in the
sump, flooding that exceeds the pump's capacity,
electrical or mechanical failure in the pump, etc.)
may prevent your pump from functioning normally. To
prevent possible water damage due to flooding, consult
your dealer about installing a secondary sump pump, a
DC backup sump pump, and/or a high water alarm. See
Troubleshooting in this manual for information about
common sump pump problems and remedies. For more
information, see your dealer or call customer service at
800-468-7867.
1. Know the pump application, limitations, and
potential hazards.
2. Disconnect the power before servicing.
3. Release all pressure within the system before
servicing any component.
4. Drain all water from the system before servicing.
5. Secure the discharge line before starting the pump.
An unsecured discharge line will whip, possibly
causing personal injury and/or property damage.
6. Check the hoses for a weak or worn condition before
each use. Make certain all connections are secure.
7. Periodically inspect the sump, pump and system
components. Keep free of debris and foreign objects.
Perform routine maintenance as required.
8. Provide a means of pressure relief for pumps whose
discharge line can be shut-off or obstructed.
9. Personal Safety:
a. Wear safety glasses at all times when working
with pumps.
b. Keep the work area clean, uncluttered and
properly lighted – replace all unused tools
and equipment.
c. Keep visitors at a safe distance from work area.
d. Make the workshop child-proof – with padlocks,
master switches, and by removing starter keys.
10. When wiring an electrically driven pump, follow all
electrical and safety codes that apply.
11. This equipment is only for use on 115 volt
(single phase) and is equipped with an approved
3-conductor cord and 3-prong, grounding-type plug .
Risk of electric shock . Can shock, burn
or kill. To reduce risk of electric shock, pull plug
before servicing. Pump is supplied with a grounding
conductor and grounding-type attachment plug. Be
sure it is connected only to a properly grounded
grounding-type receptacle.
For parts or assistance, call Simer Customer Service at 800-468-7867
Where a 2-prong wall receptacle is encountered, it
must be replaced with a properly grounded 3-prong
receptacle installed in accordance with codes and
ordinances that apply.
12. All wiring should be performed by a
qualified electrician.
13. Make certain the power source conforms to the
requirements of your equipment.
14. Protect the electrical cord from sharp objects,
hot surfaces, oil, and chemicals. Avoid kinking
the cord. Replace or repair damaged or worn
cords immediately.
15. Do not touch an operating motor. Modern motors
are designed to operate at high temperatures.
16. Do not handle the pump or pump motor with wet
hands or when standing on wet or damp surface, or
in water.
Risk of electric shock . Can shock, burn
or kill. If your basement has water or moisture on
floor, do not walk on wet area until all power has
been turned off. If shut-off box is in basement, call
electric company or hydro authority to shut-off
service to house, or call your local fire department
for instructions. Remove pump and repair or re place.
Failure to follow this warning can result in fatal
electrical shock.
17. Do not install the pump in any location classified as
hazardous by the National Electric Code, ANSI/NFPA
70-1984 or the Canadian Electrical Code.
Installation
1. Install the pump in a sump pit with a minimum
diameter of 12" (305mm). Construct the sump pit of
tile, concrete, steel or plastic. Check local codes for
approved materials.
2. The pump should not be installed on clay, earth or
sand surfaces. Clean the sump pit of small stones
and gravel which could clog the pump. Keep the
pump suction housing clear of debris.
3. Install the pump in the pit so the switch operating
mechanism has maximum possible clearance. Do
not lift the pump by the power cord.
4. Install an in-line check valve to prevent flow
backwards through the pump when the pump
shuts off.
5. Install the discharge plumbing .
A. When using rigid pipe, use plastic pipe. Wrap
the threads with PTFE pipe thread sealant
tape. Screw the pipe into the pump hand tight
+1 – 1-1/2 turns.
NOTICE Do not use ordinary pipe joint
compound on plastic pipe. Pipe joint compound
can attack plastics.
4