Chart A – Kit Selection Guide
Model
STAR-02A-11-F
STAR-02A-81-F
STAR-02A-21-F
STAR-02A-71-F
STAR-02A-41-F
STAR-02A-61-F
STAR-05A-81-F
STAR-05A-21-F
STAR-05A-71-F
STAR-05A-41-F
STAR-05A-61-F
STAR-06A-83-F
STAR-06A-23-F
STAR-06A-71-F
STAR-06A-43-F
STAR-06A-63-F
STAR-14A-83-F
STAR-14A-23-F
STAR-14A-71-F
STAR-14A-43-F
STAR-14A-63-F
** Includes Grill(s)
ELECRIC SHOCK HAZARD. Disconnect all power
before servicing or replacing heating elements.
The reflectors should be kept clean to obtain the maximum
radiant output.
Element Replacement
1. Remove Terminal Box Cover.
2. Disconnect lead wires from heater terminals and disengage box
from conduit /cable fitting.
3. Remove safety grills (if installed).
4. Remove retainer screw located on the reflector at the terminal end.
5. Loosen (2), 3/8" nuts from the terminal box bracket located on
the back of the heater and slide the entire heating element
assembly out of the reflector assembly.
OPTIONAL ACCESSORIES
Grill
Disconnect
Kit
Kit
PCN 111878
PCN 111878
PCN 111878
PCN 111878
PCN 111878
PCN 111878
PCN 111894
PCN 111894
PCN 111894
PCN 111894
PCN 111894
PCN 340662
PCN 340638
PCN 340638
PCN 340638
PCN 340638
PCN 340638
PCN 340857
PCN 340857
PCN 340857
PCN 340857
PCN 340857

MAINTENANCE

4
Hanger
Wall Mount
Kit
Ground Fault
NA
PCN 340777
PCN 340785
PCN 340793
PCN 340806
PCN 340814
PCN 340777
PCN 340785
PCN 340793
PCN 340806
PCN 340654
PCN 340814
PCN 340777
PCN 340785
PCN 340793
PCN 340806
PCN 340814
PCN 340777
PCN 340785
PCN 340793
PCN 340806
PCN 340814
6. Remove wires and jumper straps as required to replace the
failed heating element(s).
7. Remove bulkhead fitting nuts and washers.
8. Remove failed element and replace with a new element.
Replace only with genuine Chromalox "Arctic End" elements.
Use of other elements will cause excess temperatures inside
terminal box.
9. Place gasket on the bulkhead fitting and insert terminals and
fittings into the element holes in the terminal box.
10. Place washers and nuts on bulkhead fittings and tighten.
11. Replace wiring and jumper straps ( see Fig. 1).
12. Reassemble by following the reverse procedures (steps 5
through 1).
Portable
Cart Kit**
NA
NA
NA
NA
NA
NA
PCN 340620
PCN 340620
PCN 340620
PCN 340620
PCN 340620
PCN 340830
PCN 340830
PCN 340830
PCN 340830
PCN 340830
PCN 340849
PCN 340849
PCN 340849
PCN 340849
PCN 340849

Advertisement

loading

This manual is also suitable for:

Star-02a-81-fStar-02a-21-fStar-02a-71-fStar-02a-41-fStar-02a-61-fStar-05a-81-f ... Show all