Ducane CMP A Series Installation Instructions Manual page 11

Table of Contents

Advertisement

For
bottom
(end)
return installations,
the above
optional
external rack may be used, it" the unit was not provided
with an
internal
filter.
Minimum
filter size and suggested
filter materials
are shown in Table
1.11: (If differant
type filter is used, it must be
an equivalent
high airflow capacity).
Table 1.11 FILTER SIZE SELECTION
B'IU
FILTER SIZE
END
_g_
INPUT
SIDE-RETURN
RETURN
5"0.000
15 V1 X25
12X25
75.oooI
100.0(30
i
15 IA X 2.5
IS Vl X 25
t_arm din' na,ta
t.=.
125.0001
15V2 X2.5
19X25
Here's How Your Heating
System
Works:
The furnace operates automatically.
A thermostat
that you set
at the temperature
most comfortable
to you controls it. When the
inside
temperature
drops below
this setting,
your thermostat
will
turn on the heating
system.
When
the
thermostat
calls
for
heat,
power
from
the
a'ansformer
energizes
the fan control
board.
The
fan control
energizes
the induced
draft blower
motor.
The pressure switches
will close and inidate the ignition sequence.
The SmartValve"
will
energize
the pilot gas valve.
The SmartValve"
will light the pilot
automatically.
If the pilot flame
is sensed,
the main valve will
open and the pilot flame will light the burners.
The
electronic
fan control
will
automatically
turn on the
blower
after 30 seconds.
Fan ON control is not adjustable.
The air
moved
over
the heating
element
by the blower
is warmed
and
passes
through the ducts to the room registers.
When
the thermostat
is satisfied,
the circuit
is de-energized
and the main gas valve stops gas flow to the burners.
The blower
continues
to run until the selectable
fan OFF time period
has
expired.
(See Figure 2.14 for setting the desired fan OFF time.)
The heat-sensing switch performs as the high temperature
limit switch.
If the furnace overheats for any reason, the limit
switch opens, breaking the circuit to the main gas valve. If the
limit is activated, check for a restriction in the duct system (i.e.,
dirty filters, blocked duct'work, closed registers, etc.). The blower
motor and inducer motor will be energized as the unit cools. As
soon as the limit switch closes the burners will relight, but unless
the overheating condition is corrected, the furnace will cycle on
limit. If the furnace is cycling on the limit switch corrective action
must be taken.
Failure to correct this condition could possibly
damage the heat exchangers
and may not be covered by the
walTanty.
WARNING
Should overheating
occur, or the gas supply fail
to shut OFF, turn off the manual gas valve to the
appliance
BEFORE
turning
off the
electiical
supply.
A failure to adhere to this warning can
result in a fire or explosion
and bodily harm.
This furnace is equipped with a Honeywell SV9501 "Hob
Surface Pilot" ignition control. If the unit does not light due to a
gas interruption, the system will continue attempting to light until
the gas is restored and the unit lights or the system is turned
"OFF". The sequence of lighting is as follow:.
30 sec.
Trial for ignition - igniter & pilot valve energizes
25 see.
Lockout - igniter & pilot valve de-energized
30 sec.
Trial for ignition - igniter & pilot valve energized
5 min.
Lockout - igniter & pilot valve de-energized
As long as the thermostat is calling for heat this cycle will
repeat indefinitely until the pilot lights.
STARTUP
AND OPERATIONAL
CHECKOUT
WARNING
Do not use this furnace as a construction
heater:
Use
of this furnace
as a construction
heater
exposes
the furnace
to abnorma!
conditions,
contaminated
combustion
air and the lack of air
f'tlters. Failure to follow this warning can lead to
premature
furnace
failure
and/or
vent
failure
which could result in a fire hazard and/or bodily
harm.
The automatic gas valve controls the flow of gas to both the
pilot and main burners.
The ignition system control switch built
into the automatic valve body has 2 positions:
"OFF" and "ON"
(Figure 1.12). To shut off gas manually: Slide switch from "ON"
to "OFF" position. When in "OFF" position, the main bun_rs and
the pilot are extinguished.
This furnace is equipped with an automatic hot-surface pilot
ignition control and does not require the manual lighting of a pilot
for furnace operation.
20246506
Issue 9939
Page 11 of 22