ON
Figure 34 - Room Temperature Setting
SMART THERMOSTAT
The Smart Thermostat adjusts flame height
in accordance to differences between set
temperature and room temperature. As room
temperature gets closer to set temperature the
smart function will modulate the flame lower.
As room temperature cools, it will modulate
the flame higher.
To activate this function, press THERMOSTAT
button until the word SMART appears to the
right of temperature bulb graphic on display.
Use UP/DOWN arrow button to set desired
room temperature. The control system will
cycle the fireplace on or off to maintain se-
lected temperature.
SMART
MAX
Figure 35 - Smart Thermostat Setting
121486-01F
OPERATION
Continued
CHILD SAFETY LOCK-OUT
Room
This function lets you deactivate the remote
Temperature
control buttons. It is active when the lock icon
is lit on the display.
Set
To activate, press MODE button and UP ar-
Temperature
row button at the same time. To deactivate,
press again.
PROGRAMING HAND-HELD REMOTE
CONTROL TO RECEIVER
If your remote ever needs to be replaced you
will not need to replace the receiver.
To program receiver with a new hand-held
remote, insert a small pin or paper clip into
hole on receiver face plate marked PRG. The
receiver will beep 3 times to indicate it is ready
to accept a new remote transmitter. Press
the ON/OFF button on your remote and the
receiver will beep 4 times to confirm it receives
commands from the new remote.
www.desatech.com
ON
Figure 36 - Child Safety Lock-Out
ON REMOTE OFF
Figure 37 - Programing Remote Control
to Receiver
To Program
Receiver
PRG
21