LG DLHX4072 Series Owner's Manual page 23

Hide thumbs Also See for DLHX4072 Series:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION
INSTRUCTIONS
23
Connecfing
elecfric
dryers
(conf.)
USA only
-AWARNING
. Connect the power cord to the terminal
block. Each
colored
wire should be connected
to same color screw.
Wire color indicated
on manual
is connected
to the same
color screw in block.
Failure to follow
these instructions
may result in a short or overload.
. Grounding
through
the neutral
conductor
is prohibited
for: (1) new branch-circuit
installations,
(2) mobile
homes,
(3) recreational
vehicles, and (4} areas where local codes
prohibit
grounding
through
the neutral
conductor.
Four-wire
connection
for electric
dryers:
Direct
wire
, A 4-wire connection
is required for all mobile
and manufactured
home installations,
as well as all new construction
after January 1,
1996.
. A UL-listed
strain relief is required.
1. Remove 5 inches (12.7 cm) of the outer covering
from the wire.
Remove 5 inches of insulation
from the ground
wire. Cut off
approximately
11/2inches (3.8 cm) from the other three wires
and strip 1 inch (2.5 cm) insulation
from each wire. Bend the
ends of the three shorter wires into a hook shape.
1" (2.5 cm)
I-q
___1_.._
Ground Wire
(12.57'cm)_
. Use UL-listed 4=wire #10 AWG-minimum copper conductor
cable.
. Allow at least 5 ft. (1.5 m) length to allow for removal and
reinstallation
of the dryer.
3. Transfer the dryer's ground
wire from behind the green ground
screw to the center screw of the terminal
block. Attach the two
hot leads of the power cable to the outer terminal
block screws.
Attach the white
neutral wire to the center terminal
block
screw. Attach the power cable ground
wire to the green ground
screw. TIGHTEN ALL SCREWS SECURELY Reinstall the terminal
block access cover.
Hot
Neutral
(Black)
(White)
--_-"__1_,_
Hot
Ground
(Red)
Screw
¢1___
White Wire
k,_
-
moved from
/
_
Ground Screw
Power Cord,"
GroundWire
2. Remove the terminal
block access cover on the upper back of
the dryer. Install a UL-listed strain relief into the power cord
through-hole;
then thread the power cable prepared
in Step 1
through
the strain reliefl
__
_.._...
Terminal
__
Block
{
"_f
__ _
sUtLraLiinStRe_ief
UL-Listed
/
4-Wire Power
Cord

Advertisement

Chapters

Table of Contents
loading

Table of Contents