11
Centering the needle in the needle hole
.10
Requirement
The needle should enter the needle hole exactly in the centre.
Fig. 11 - 07
Position the needle directly above the needle hole.
Loosen screws 1, 2 and 3.
Position the needle bar frame 4 in accordance with the requirement
Tighten screw 2 and slightly tighten screw 3.
By tightening screw 1 draw the inner guide stud towards the eye of the needle bar frame 4.
Turn the balance wheel a few times to avoid a distortion of the needle bar frame 4.
Tighten screw 3.
Adjustment
1
4
2
requirement.
requirement
requirement
requirement
3
11 - 8