19. 10°C HEAT OPERATION
The 10°C HEAT operation functions by pressing 10°C HEAT button on the remote controller.
The 10°C HEAT operation is almost the same operation as below settings.
( Table16 )
Mode
Setting temperature
Fan mode

20. ECONOMY OPERATION

The ECONOMY operation functions by pressing ECONOMY button on the remote controller.
The ECONOMY operation is almost the same operation as below settings.
( Table17 )
Mode
Target temperature

21. BASE HEATER OPERATION

The base heater is operated as shown in Figure 13.
( Fig.13 : Base heater control )
When outdoor
temperature drops
2°C
When the compressor stops, Base heater is OFF.
When the outdoor fan motor stops, Base heater is OFF.
In the cooling mode, Base heater is OFF.
In the defrost operation, Base heater maintains the same status
as before the compressor stops.
Heating
10°C
AUTO
Cooling/ Dry
Setting temp.+1°C
When outdoor
temperature rises
OFF
5°C
ON
Heating
Setting temp.-1°C