Disassembly; Outer Elements; Coffee Grinder - Philips Saeco Gaggia Unica RI 9933 Service Manual

Table of Contents

Advertisement

GAGGIA UNICA
7.1.

Outer elements

Unscrew the marked
screws and remove the
fi nger protection
Unscrew the marked screws, remove the
fork and extract the front casing cover
Undo the marked screws, remove the RH and LH side cover
7.2.

Coffee grinder

Loosen the screws as illustrated
and remove the sound insulating
cover of the coffee grinder
Saeco International Group
Remove the water tank, coffee container cover, water
recovery tray, dregs drawer, brewing unit, hot water/
steam knob.
Firmly raise the top
cover
To remove the front casing, unscrew the marked screws,
remove the fork spring and extract the cover and the
fi tting of the steam pipe and extract it from the casing.
Raise the coffee grinder and
remove the connections
Unhook the front panel, raising it and extract
the electric connections
When reassembling the coffee
grinder, make sure the spring is
repositioned correctly (see photo)