Machine parameters and performance

Minimum
PRODUCT
quantity
QUANTITY
(Puls.)
Espresso
Long coffee
Pre-ground
Hot water
Steam for
frother
RINSE
When performed
No. of pulses
Stopping option
User disable option
Production/Service
department disable option
No. of pulses user
adjustment option
No. of pulses Production/
Service department
adjustment option
Pulse range
(Min. – Max.)
Hardness
Water hardness
1
Soft (up to 7°dH)
2
Medium (7°-14dH)
3
Hard (15°-21°dH)
4
Very hard
(over 21°dH)
The default water hardness level is 3. Each litre of water corresponds to approximately 2,000
pulses
Saeco International Group
Default
quantity
(Puls.)
50
130 - 170
70
200 - 230
Continues until the water supply has been exhausted (capacitive sensor)
Initial rinse
When the machine is switched
on and the boiler temperature is
Yes, by pressing any key
Descaling cycle frequency
Without water fi lter
240 litres (480,000 pulses)
120 litres (240,000 pulses)
60 litres (120,000 pulses)
30 litres (60,000 pulses)
Maximum
quantity
programmable
(Puls.)
600
600
No
Continues for 400 pulses
≤ 50°C
130
No
No
No
No
No
Rev. 01
02 TECHNICAL SPECIFICATIONS
User
Programm. by
Production / Service
Yes
Yes
Final rinse
When the machine is switched
off electronically, manually or
automatically after 60', if at least
one coffee has been dispensed,
before switching off
100
Yes, by pressing any key
No
No
No
No
No
With water fi lter
480 litres (960,000 pulses)
240 litres (480,000 pulses)
120 litres (240,000 pulses)
60 litres (120,000 pulses)
No
No
Page