Unit Installation; Location; Ground Installation; Roof Installation - York E4FH018 Installation Instructions Manual

Stellar outdoor split-system heat-pump 12 seer
Table of Contents

Advertisement

515.28-N3Y
TO
THERMOSTAT
BLOWER
MOTOR
RELAY
TO
COIL
NOTE: ALL OUTDOOR WIRING
MUST BE WEATHERPROOF
SEAL OPENING(S) WITH PERMAGUM OR EQUIVALENT
FIGURE 1: TYPICAL INSTALLATION

UNIT INSTALLATION

LOCATION

Before starting the installation, select and check the suitability
of the location for both the indoor and outdoor unit. Observe
all limitations and clearance requirements.
The outdoor unit must have sufficient clearance for air
entrance to the condenser coil, for air discharge and for ser-
vice access. See Figure 1.
NOTE: For multiple unit installatins, units must be spaced a
minimum of 18 inches apart. (Coil face to coil face.)
If the unit is to be installed on a hot sun exposed roof or a
black-topped ground area, the unit should be raised suffi-
ciently above the roof or ground to avoid taking the accumu-
lated layer of hot air into the outdoor unit.
Provide an adequate structural support.

GROUND INSTALLATION

The unit may be installed at ground level on a solid base that
will not shift or settle, causing strain on the refrigerant lines
and possible leaks. Maintain the clearances shown in Figure
1 and install the unit in a level position. Isolate the base from
the structure to avoid noise or vibration transmission.
Normal operating sound levels may be objectionable if the
unit is placed directly under windows of certain rooms (bed-
rooms, study, etc.).
3
TO POWER
SUPPLY
NEC CLASS 1
WIRING
NEC CLASS 2
WIRING
WEATHERPROOF
DISCONNECT
SWITCH
24" SERVICE
ACCESS CLEARANCE
REQUIRED
Condensate will drain from beneath the coil of the outdoor
unit during the defrost cycle. Normally this condensate may
be allowed to drain directly on the ground.
The outdoor unit should not be installed in an area
where mud or ice could cause personal injury.
Remember that condensate will drip from the unit coils
during heat and defrost cycles and that this conden-
sate will will freeze when the temperature of the out-
door air is below 32*F..
Elevate the unit sufficiently to prevent any blockage of the air
entrances by snow in areas where there will be snow accu-
mulation. Check the local weather bureau for the expected
snow accumulation in your area.

ROOF INSTALLATION

When installing units on a roof, the structure must be capable
of supporting the total weight of the unit, including a pad, lin-
tels, rails, etc., which should be used to minimize the trans-
mission of sound or vibration into the conditioned space.
Isolate the unit from rain gutters to avoid any possible wash
out of the foundation.
48" OVERHEAD
CLEARANCE
12" REAR
REQUIRED
AND SIDES
CLEARANCE
REQUIRED
Unitary Products Group
Sit unit on
rubber
elevator
grommets
to reduce
noise and
allow for
proper
drainage.