HOW YOUR HEAT PUMP WORKS . 2
SYSTEM OPERATION . . . . . . . . . . . 2
THERMOSTATS . . . . . . . . . . . . . . . . . . . .2
FAN OPERATION SELECTION . . . . . . . .2
HEATING CYCLE . . . . . . . . . . . . . . . . . . .2
COOLING CYCLE . . . . . . . . . . . . . . . . . . .3
TO MAXIMIZE OPERATING
EFFICIENCY . . . . . . . . . . . . . . . . . . . 3
HEATING CONSERVATION . . . . . . . . . .3
COOLING CONSERVATION . . . . . . . . . .3
CARE OF SYSTEM . . . . . . . . . . . . . . 3
COIL CARE . . . . . . . . . . . . . . . . . . . . . . . .3
FILTER CARE . . . . . . . . . . . . . . . . . . . . . .3
SERVICE CALLS . . . . . . . . . . . . . . . 4
PARTS INFORMATION . . . . . . . . . . . . . .4
CHARACTERISTICS OF HEAT
PUMPS . . . . . . . . . . . . . . . . . . . . . . . 4
A CONSTANT HEAT . . . . . . . . . . . . . . . .4
WATER RUN-OFF . . . . . . . . . . . . . . . . . .4
OUTDOOR COIL DEFROSTING . . . . . . .4
OWNER'S MANUAL
O U T D O O R S P L I T- S Y S T E M
H E AT P U M P
1 5 S E E R 2 . 5 TO 5 TON S
MODELS:
E4TS030
E4TS036
E4TS048
E4TS060
035-16473-001 Rev. A (202)

Advertisement

loading

Summary of Contents for York E4TS030

  • Page 1 O U T D O O R S P L I T- S Y S T E M H E AT P U M P 1 5 S E E R 2 . 5 TO 5 TON S MODELS: E4TS030 E4TS036 E4TS048 E4TS060...
  • Page 2: System Operation

    035-16473-001 Rev. A (202) ongratulations . . . On your purchase of one of the most versatile heat pump systems available in the industry today. This Stealth series high effi- ciency system has been precision designed, manufactured of high quality materials and has passed many vigorous inspections and tests to ensure years of satisfactory service.
  • Page 3 All E*TS systems are equipped with balance point control to provide even more efficient operation. This control will prevent the electric heater from being energized when the outdoor air is above some predetermined temper- ature setting (0 to 45° F). At higher temperatures, your system will provide all the heat your home will ever need.
  • Page 4 Wait 5 minutes. If system does not start, call qualified serviceman. Obtain the fault code number of times the Emergency Heat light on the thermostat flashes between pauses. Subject to change without notice. Printed in U.S.A. Copyright © by York International Corp. 2002. All rights reserved. Unitary Products Group...