5-12. Selecting Manual MIG Welding (DX Models Only)
6
OM-246 691 Page 28
4
5
1
2
3
1
Setup Button
2
Manual MIG Mode Indicator
Press and hold setup button for ap-
proximately 3 seconds to select
manual MIG mode and lite indicator.
3
Voltage Control S2
4
Wire Feed Speed (WFS)/Trim
(Arc Length) And Line Input
Adjustment Control R1
5
Digital Display Meter
.
In Manual MIG mode, the operat-
or may need to adjust main weld-
ing parameters for specific arc
characteristics
Use setup button to select desired
parameter: voltage, amperage, or
preset wire feed speed and lite cor-
responding LED (V, A, or %).
The value of the selected parameter
is displayed on meter.
Turn voltage control clockwise to in-
crease voltage.
Turn wire feed speed control clock-
wise to increase wire feed speed.
Select trigger mode 2T or 4T accord-
ing to Section 5-7.
Spool Gun Operation:
6
Spool Gun Receptacle
For spool gun connection and opera-