4-12. Selecting Manual MIG Welding

P3
Set Manual MIG welding process using P3
push button.
In Manual MIG mode, the operator may
need to adjust main welding parameters for
specific arc characteristics. Wire feed
speed and arc voltage will appear on D1
and D2.
D1
During Setting :
D1 value is default voltage setting of 18.5 V
(range is 10.0 V to 50.0 V).
D2 value is default wire feed speed setting
of 5.0 m/min (range is 1.0 m/min to 20.0
m/min).
D2
During MIG Welding:
D1 value is Measured Welding Voltage in
Volts.
D2 value is Measured Welding Amperage
in Amperes.
See Wire Feeder manual for remaining
manual MIG settings.