Precor C842 Service Manual page 50

Hide thumbs Also See for C842:
Table of Contents

Advertisement

the seat. Remove the plate. The cable may be stuck to the plate with double sided tape.
19. Remove the two screws that fasten the plate to the seat rail. Extract enough cable from the
seat rail to access the cable connectors. Carefully, pull all excess cable out from under the
seat, so that it is looped behind the seat. See Diagram 7.9. Disconnect the two cables.
Diagram 7.9 - Hand Held Heart Rate Cable
Seat
Cable
20. Slide the seat rail cable back into the access hole. The seat carriage must travel over this
cable, so it must be below the surface of the seat rail. Release the seat lever, hold the cable
attached to the seat straight back from the seat as you slide the entire seat and seat
carriage off of the rear of the seat rail. See Diagram 7.10.
Diagram 7.10 - Hand Held Heart Rate Cable
21. If you are performing maintenance on the seat wheels or seat lever perform the appropriate
tasks between steps 6 and 11. Return to step 31. when the maintenance procedures are
complete. If you are performing maintenance on the hand held heart rate cables in the seat
assembly, continue with step 22.
C842, C842i, C846, C846i Upright and Recumbent Cycle
Seat Rail
Cable
Page 50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C842iC846C846i

Table of Contents