York P*UR 40 Installation Instructions Manual page 7

Table of Contents

Advertisement

035-14370-000
F R O N T
B
P o w e r
V e n t C o n n e c t i o n
2 0
( v e n t s i z e )
W i r i n g
7 / 8 " K . O .
D
5 - 3 / 8
1 - 7 / 8
F
E
F R O N T
T O P I M A G E / R E T U R N E N D
ALL DIMENSIONS ARE IN INCHES, AND ARE APPROXIMATE.
FIGURE 2 : DIMENSIONS - DOWNFLOW/HORIZONTAL MODELS: P*DH/FG9-DH/G9T-DH
TABLE 2: RATINGS & PHYSICAL / ELECTRICAL DATA - UPFLOW MODELS (P*DH/FG9-DH/G9T-DH)
MODELS P*DH/FG9-DH/
G9T—DH
INPUT
OUTPUT
MBH
MBH
40
37
60
55
80
75
80
75
100
95
120
112
1.
AFUE numbers are determined in accordance with DOE test procedures
2.
Wire size and overcurrent protection must comply with the National Electrical Code (NFPA-70-latest edition).
For altitudes above 2,000 ft., reduce capacity 4% for each 1,000 ft. above sea level. Refer to Form 650.74-N1.1V.
Wire size based on copper conductors, 60°C, 3% voltage drop.
Continuous return air temperature must not be below 55°F.
Unitary Products Group
B
3 / 4
C o n d e n s a t e
D r a i n A c c e s s
3 - 1 / 4 X 3
A i r I n t a k e
4 5
3 - 5 / 8 x 3 - 5 / 8
( G
C o n n . S i z e /
P i p e S i z e )
A
L E F T S I D E
A
1-3/8
19-1/4
C
1-3/8
8
G A S I N L E T
3 7/8
F R O N T
H
B O T T O M
I M A G E / S U P P L Y E N D
CABINET
1
AFUE
WIDTH
.
NOM
CFM
800
14-1/2
91.0
1200
17-1/2
91.0
1200
17-1/2
91.0
1600
21
91.0
2000
21
91.0
2000
24-1/2
91.0
D
2 0
( V e n t C o n n e c t i o n )
T ' S T A T W I R I N G
7 / 8 " K . O .
1 - 3 / 4
3 5
5 - 1 / 4
1 8 - 1 / 2
1 - 1 / 4
3 - 3 / 4
G A S I N L E T
1 - 1 / 4 " X 2 - 1 / 2 "
6 - 1 / 4
2 - 3 / 4
2 8 - 1 / 2
MODELS P*DH/
A
FG9-DH/G9TDH
40 /37 / 800 / A
14-1/2
60 /55 / 1200 / B
17-1/2
80 /75 / 1200 / B
17-1/2
80 /75 / 1600 / C
21
100 /95 / 2000 / C
21
120 /112 / 2000 / D
24-1/2
1.
Vent pipe must be increased to 3" on this model.
@
.
CFM
MAX
IR
A
MEAN AIR
OUTLET
TEMP
TEMP
AIR
°
RISE
F
DIA
. °
RISE
TEMP
F
25 - 55
856
155
35 - 65
1018
165
35 - 65
1370
165
30 - 60
1563
160
40 - 70
1582
170
40 - 70
1885
170
C o n d e n s a t e
D r a i n A c c e s s
3 - 1 / 4 X 3
6 - 1 / 2
A i r I n t a k e
1 6 - 3 / 4
3 - 5 / 8 x 3 - 5 / 8
3 - 3 / 4
( G
C o n n . S i z e /
P i p e S i z e )
7 - 1 / 2
1 - 1 / 4
A L T . G A S I N L E T
4 - 1 / 8
1 - 1 / 4 " X 2 - 1 / 2 "
R I G H T S I D E
B
C
D
13-1/4
11-3/4
2
16-1/4
14-3/4
2
16-1/4
14-3/4
2
19-3/4
18-1/4
2
19-3/4
18-1/4
2
23-1/4
21-3/4
1
2 (3)
BLOWER
MAX OVER
TOTAL
UNIT
WIDTH
PROTECT 2
AMPS
(
)
IN
HP
(
.)
IN
10
6
1/4
9.0
11
8
1/2
9.0
11
8
1/2
9.0
11
8
3/4
12.0
11
10
1
12.0
11
10
1
12.0
650.75-N4U
E
F
G
5-1/8
2-1/2
2
6-5/8
2-1/4
2
6-5/8
2-1/4
2
8-3/8
2-1/4
2
8-3/8
2-1/4
2
10-1/8
2-1/4
3
MIN WIRE
-
(
)
SIZE
AWG
CURRENT
@ 75
.
FT
ONE WAY 2
20
14
20
14
20
14
20
14
20
14
20
14
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents