To the Installer This guide is intended for the technician responsible for installing the AP 100 802.11b Access Port. It is also assumed that the technician is familiar with Ethernet LAN-based networking concepts. The purpose of this document is to provide specifications, features and guidelines for the installer to use during installation.
Also, review standard practices for preventing accidents. Indicates tips, hints and special requirements. Care is required. Disregarding cautions can cause data loss or equipment damage. Indicates a potentially dangerous condition or procedure that only Symbol-trained personnel should attempt to correct or perform.
Warnings • Only trained and qualified personnel are allowed to install this equipment. • Read all installation instructions and site survey reports, and verify correct equipment installation before connecting the system to its power source. • Remove any jewelry (rings, watches, necklaces, etc.) while installing this equipment. •...
Introduction The AP 100 802.11b Access Port provides area RF coverage to 802.11b wireless network devices. The AP 100 Access Port includes different installing options, allowing best placement for optimum range. The standard mounting base allows securing the unit to most surfaces with two screws.
Page 8
The AP 100 Access Port has two separate antenna configuration models: an internal antenna model and external antenna connector model. The external antenna connector model allows for Symbol approved antennas to be attached to the AP 100 Access Port. The two models are shown in the following figures.
Specifications Operating Voltage 48VDC (typical) 36VDC to 57VDC (range) Operating Current 10mA to 150mA Peak Current 250mA Operating Temperature -20°C to 50°C (-4°F to 122°F) Operating Humidity 5% to 95% Storage Temperature -40°C to 70°C (-40°F to 158°F) Altitude 2.4km (operating max) 4.6km (storage max) Drop .8 meters (31.50in.) to concrete Electrostatic Discharge Internal Antenna Model...
• Ceiling-Mount Badge • Ceiling-Mount Light Pipe Screw • Installation Guide Review site survey and network analysis reports to determine the method for AP 100 Access Port installation. For a list of available Symbol antennas, please visit the Symbol Web site at:...
Surface Mounting The AP 100 Access Port will mount to most surfaces using the mounting screws and surface-mount assembly. Note: Refer to installation plans for the designated connector.
Above-Ceiling Mounting Some installations require AP 100 Access Port mounting above the ceiling tile. This type of installation hides the unit and cable away from visual access. Use this installation in plenum-rated ceiling configurations. Verify that the attaching Ethernet cable is also plenum rated.
For external antenna power settings, please refer to the WS 5000 Wireless Switch Reference Guide. Power/Data (RJ-45) Connection The AP 100 Access Port receives power from the Ethernet cable. It supports the following Symbol-branded Power-Over-Ethernet devices: • Symbol Power Injector 1 Port •...
Customer Support Symbol Technologies provides its customers with prompt and accurate customer support. Use the Symbol Support Center as the primary contact for any technical problem, question or support issue involving Symbol products. If the Symbol Customer Support specialists cannot solve a problem, access to all technical disciplines within Symbol becomes available for further assistance and support.
Page 16
Winnersh Triangle, Berkshire, RG41 5TP United Kingdom Telephone: 0800-328-2424 (Inside UK), +44 118 945 7529 (Outside UK) For other sales offices use the Symbol Services Web site for contact information http://www.symbol.com/services/howto/howto_contact_us.html Web Support Sites Comprehensive On-line support is available at the MySymbolCare Web site.
Page 17
Symbol Developer Program Web site http://devzone.symbol.com Symbol Knowledge Base http://kb.symbol.com/register.asp Additional Information Obtain additional information by contacting Symbol at: Telephone: 1-800-722-6234 (Inside North America), +1-631-738-5200 (Inside/Outside North America) http://www.symbol.com/...
Regulatory Information All Symbol devices are designed to comply with rules and regulations in locations they are sold and will be labeled as required. Any changes or modifications to Symbol Technologies equipment, not expressly approved by Symbol Technologies, could void the user’s authority to operate the equipment.
Power Supply Note: Use only a Symbol-approved power supply output rated 48VDC. The power supply is certified to EN60950 with SELV outputs. Hinweis: Benutzen Sie nur eine Symbol Technologies genehmigt Stromversorgung in den Ausgabe: -48VDC. Die Stromversorgung ist bescheinigt nach EN60950 mit SELV Ausgaben •...
Page 20
To comply with European and International regulations, use only Symbol approved antennas. To ensure the correct antenna configuration and power settings are used, refer to the Wireless LAN Switch System Reference Guide. For a list of available Symbol antennas, please visit the Symbol Web site at: http://www.symbol.com/wireless/...
• Italy requires a user license for outside usage. Statement of Compliance Symbol Technologies, Inc., hereby, declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A Declaration of Conformity may be obtained from http://www2.symbol.com/doc/ Other Countries Mexico –...
Patents This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No. 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,760,248; 4,806,742; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144;...
Page 24
Symbol Technologies, Inc. One Symbol Plaza Holtsville, NY 11742-1300 www.symbol.com 72E-64525-01 Revision A...