Operation Data - Toshiba RAS-18SAV2-E1 Service Manual

Split type
Table of Contents

Advertisement

7-2. Operation Data

<Cooling>
Tempeature
Model name
condition(°C)
Indoor
Outdoor
27/19
35/24
18SKV-E
18SKV2-E
<Heating>
Tempeature
Model name
condition(°C)
Indoor
Outdoor
20/15
7/6
18SKV-E
18SKV2-E
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchaner path U bent.
(Thermistor themometer)
2. Connecting piping condition : 7.5 m
Standard
RAS-
pressure
P (MPa)
0.9 to 1.1
Standard
RAS-
pressure
P (MPa)
2.5 to 2.6
Heat exchanger
pipe temp.
T1 (°C)
T2 (°C)
11 to 13
40 to 42
Heat exchanger
pipe temp.
T1 (°C)
T2 (°C)
40 to 42
1 to 3
– 20 –
FILE NO. SVM-11031
Indoor
Outdoor
fan mode
fan mode
High
High
Indoor
Outdoor
fan mode
fan mode
High
High
Compressor
revolution
(rps)
67
Compressor
revolution
(rps)
79

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-18skv2-eRas-18sav-e3Ras-18skv-e

Table of Contents