Wiring Connection - Toshiba RAS-4M23SACV-E Installation Manual

Hide thumbs Also See for RAS-4M23SACV-E:
Table of Contents

Advertisement

Wiring Connection

1.
Remove the side panel and cord clamp from the outdoor unit.
2.
Connect the connecting cable to the terminal as identified by the matching numbers on the terminal block of indoor and outdoor
unit.
3.
Insert the power cord and the connecting cable fully into the terminal block and secure it tightly with screws.
4.
Use vinyl tape, etc. to insulate the cords which are not going to be used. Locate them so that they do not touch any electrical or
metal parts.
5.
Secure the power cord and the connecting cable with the cord clamp.
6.
Attach the side panel on the outdoor unit.
Stripping length of connecting cable
1 2 3
10
10
40
Earth line
Connecting
cable
4 unit (A + B + C + D) Multi
Terminal block (Connecting cable)
Screw
Connecting cable
(B unit)
Connecting cable
Connecting cable
(A unit)
Model
Power source
Maximum running current
Installation fuse rating
Power cord
Connecting cable
CAUTION
• Incorrect wiring connection may cause electrical parts to burn out.
• Be sure to comply with local regulations/codes when running the wire from outdoor unit to indoor unit. (Size of wire and wiring
method etc.)
• Every wire must be securely connected.
• If incorrect or incomplete wiring is carried out, fire or smoke may result.
• Prepare the power supply for the exclusive use of the air conditioner.
L N
10
30
30
Power cord
Connecting cable
(D unit)
Power cord
(C unit)
4 unit Multi
RAS-
RAS-
4M23SAV-E
4M23SACV-E
13.8 A
16 A breaker or fuse
(all types can be used)
H07RN–F or 60245IEC66 (1.5 mm
H07RN–F or 60245IEC66 (1.0 mm
10
40
Earth line
3 unit (A + B + C) Multi
Terminal block (Connecting cable)
Screw
Connecting cable
(B unit)
Connecting cable
(A unit)
3 unit Multi
RAS-
3M26GAV-E
220–240V ~50Hz
220V ~60Hz
13.8 A
16.4 A
2
)
H07RN–F or 60245IEC66 (2.5 mm
2
)
H07RN–F or 60245IEC66 (1.0 mm
11
Connecting cable
(C unit)
Power cord
4 unit Multi
RAS-
RAS-
4M27GAV-E
4M27GACV-E
17.0 A
16.6 A
20 A breaker or fuse
(all types can be used)
2
2
)
)
EN