Gaggia Brera Service Manual page 13

Hide thumbs Also See for Brera:
Table of Contents

Advertisement

GAGGIA
Indications
Machine in rinsing phase
- wait for the machine to complete
the procedure
Cyclic blinking
The appliance requires a
descaling cycle
Steady on
No coffee beans inside hopper
Steady on
No water
Steady on
Service door open: Close it
If the service door is opened while product is being dispensed, the appliance stops
dispensing and starts a 30 sec. countdown before cancelling the dispensing process.
The countdown can be stopped by closing the service door and operation will resume
Blinking
from its stopping point.
Turn the hot water/steam valve knob to the correct position.
If the knob is turned (open) while product is being dispensed, the appliance stops
dispensing and starts a 30 sec. countdown before cancelling the dispensing process.
The countdown can be stopped by closing the knob and operation will resume from
Blinking
its stopping point.
No brew group
If the brew group is removed while product is being dispensed, the appliance stops
dispensing and starts a 30 sec. countdown before cancelling the dispensing process.
The countdown can be stopped by re-inserting the brew group and closing the
Blinking
service door; operation will resume from its stopping point.
Refill circuit
Steady on
Empty the dreg drawer
Steady on
Insert dreg drawer
Blinking
Rev. 00 OCTOBER 2009
Causes
03 BRIEF INSTRUCTIONS
Solutions
Wait until end of procedure
Perform the descaling cycle
To enter the descaling cycle press the
aroma/pre-ground coffee key for 5
sec.
After filling the coffee bean hopper, start the
cycle again
Fill the water tank
Turn the knob to the cup
To reset the dreg counter, wait for the
icon to flash (5 sec.)
When the dreg counter is reset, the icon
flashes
02
Page
/ 03

Hide quick links: