Coolant Temperature Gauge - Daewoo CIELO EURO III Manual

Table of Contents

Advertisement

1D – 17 ENGINE COOLING
12. Connect the surge tank hose to the radiator.
13. Secure the surge tank hose with a hose clamp.
14. Connect the upper radiator hose and the lower ra-
diator hose to the radiator.
15. Secure each hose with a hose clamp.
16. Install the main cooling fan. Refer to "Electric Cool-
ing Fan – Main" in this section.
18. Refill the engine cooling system. Refer to "Draining
and Refilling the Cooling System" in this section.
19. Connect the negative battery cable.
B102D015

COOLANT TEMPERATURE GAUGE

Single Overhead Cam Engine
Removal Procedure
1. Disconnect the negative battery cable.
2. Drain the coolant below the coolant temperature
gauge level.
3. Disconnect the electrical connector from the coolant
temperature gauge.
4. Remove the coolant temperature gauge from the in-
take manifold.
A102D013
Installation Procedure
1. Install the coolant temperature gauge into the
threaded hole in the intake manifold.
Tighten
Tighten the coolant temperature gauge (SOHC) to 20
N m (15 lb-ft).
2. Connect the electrical connector to the coolant tem-
perature gauge.
3. Refill the coolant system. Refer to "Draining and Re-
filling the Cooling System" in this section.
4. Connect the negative battery cable.
A102D044
DAEWOO T-154 BL2,3

Advertisement

Table of Contents