Alarm Output - Samsung SNB-6005 User Manual

Table of Contents

Advertisement

setup screen

alarm output

1. From the Setup menu, select the
<event (
2. Click <alarm output>.
3. Set the camera's type of alarm output.
If you change the alarm output type, the alarm
`
out button on the monitoring page and alarm
output type displayed on Event Setup page will
be changed accordingly.
• Type
- Normal open : Considers "Open
circuit" status of the sensor or alarm
input device as normal, and triggers
alarm event if becomes "Closed
circuit" status.
- Normal close : Considers "Closed circuit" status of the sensor or alarm input device
as normal, and triggers alarm event if becomes "Open circuit" status.
4. Set the alarm output button.
• Mode : Sets the alarm output method.
There is difference between operations when clicked alarm output button while disabled.
`
- Pulse : It is activated during the time period specified by the duration (switching
interval) and then becomes inactive automatically.
- Active/Inactive : It maintains as activated until the user clicks the button again to
make it inactive.
• Duration : Set the alarm duration that maintains activated if the mode is set to
pulse, from 1 to 15 seconds.
5. When done, click [apply (
102_ setup screen