Alarm output

1. From the Setup menu, select the
<Event (
)> tab.
2. Click <Alarm output>.
3. Set the camera's type of alarm output.
If you change the alarm output type, the alarm
out button on the monitoring page and alarm
output type displayed on Event Setup page will
be changed accordingly.
• Type
- Normal open : Considers "Open
circuit" status of the sensor or alarm
input device as normal, and triggers
alarm event if becomes "Closed
circuit" status.
- Normal close : Considers "Closed circuit" status of the sensor or alarm input device
as normal, and triggers alarm event if becomes "Open circuit" status.
4. Set the alarm output button.
• Mode : Sets the alarm output method.
There is difference between operations when clicked alarm output button while disabled.
- Pulse : It is activated during the time period specified by the duration (switching
interval) and then becomes inactive automatically.
- Active/Inactive : It maintains as activated until the user clicks the button again to
make it inactive.
• Duration : Set the alarm duration that maintains activated if the mode is set to
pulse, from 1 to 15 seconds.
5. When done, click [Apply (
)].
English _93