NOTICE
z Be sure the engine and all accesso-
ries are off before performing main-
tenance.
z When checking the battery, remove
the ground cable from the negative
terminal ("−" mark) first and rein-
stall it last.
z Be careful not to cause a short cir-
cuit with tools.
z Take care no solution gets into the
battery when washing it.
01_SEQUOIA_U (L/O 0009)
—Checking battery fluid
Type A
Clear or
Green
Dark
light yellow
Type B
Blue
White
Red
CHECKING BY HYDROMETER
Check
the battery condition by
hydrometer color.
Hydrometer color
Condition
Type A
Type B
Green
Blue
Good
Charging necessary.
Have battery
Dark
White
checked by your
Toyota dealer.
Clear or
Have battery
light
Red
checked by your
yellow
Toyota dealer.
2001 SEQUOIA (OM34414U)

Battery recharging precautions

During recharging, the battery is pro-
ducing hydrogen gas.
Therefore, before recharging:
1. If recharging with the battery installed
on the vehicle, be sure to disconnect
the ground cable.
2. Be sure the power switch on the re-
charger is off when connecting the
charger cables to the battery and when
disconnecting them.
CAUTION
Always charge the battery in an un-
D
confined area. Do not charge the
the
battery in a garage or closed room
where there is not sufficient ventila-
tion.
Only do a slow charge (5 A or
D
less). Charging at a quicker rate is
dangerous.
The
battery
plode, causing personal injuries.
may
ex-
295