8
8.2.4
PROG
In this mode a preset week program is active, and the
appliance responds continually to demand within the
time periods set in the week program. There are two
distinct situations possible in this mode:
PROG
10:00 Monday
76ÉC
MO 11:15
Tset 75ÉC
1. The current time falls within a set time period
of the week program.
The figure shows the display with the following
information:
-
line one: the text PROG;
-
line two: the time, the day and T
alternately (2.3 "The appliance's heating
cycle");
-
line three: the next scheduled switch-off time
and the water temperature T
period;
-
line four: is empty, or depending on the
heating cycle (2.3 "The appliance's heating
cycle"), a text such as HEAT DEMAND.
PROG
12:00 Monday
76ÉC
MO 11:15
PERIOD ACTIVATED
2. The current time falls outside a set time period
of the week program.
The figure shows the display with the following
information:
line one: the text PROG;
-
-
line two: the time, the day and T
alternately (2.3 "The appliance's heating
cycle");
-
line three: the next scheduled switch-on
time;
-
line four: displays the text
PERIOD ACTIVATED.
In all modes, the temperature may at any moment
drop below the desired temperature. The appliance
then enters a heating cycle. This heating cycle is
identical (2.3 "The appliance's heating cycle") for all
basic operating modes.
Note
Setting and if necessary programming of the basic
operating modes are described in the main
menu (11 "Main menu") chapter.
50
Status of the appliance
8.3
The figure shows an example of an error condition. If
the appliance enters this condition, the display will
show the following information:
S04: SENSOR ERROR
maintenance engineer.
and T
1
net
There are various types of errors:
of the active
set
The display does not show what type of error has been
detected. A comprehensive overview of the errors is
provided elsewhere in the
manual (13 "Troubleshooting").
If, as end-user, you find the appliance in an error
condition, you may attempt to restart the appliance by
pressing the
However, if the error returns or occurs several times in
a short time you must contact your service and
and T
maintenance engineer.
1
net
8.4
The figure shows the message
SERVICE REQUIRED.Should this message appear,
then the appliance is in need of a service and
maintenance inspection. In that case, contact your
service and maintenance engineer.
the number of expired burning hours and the preset
service interval. Should the service interval have been
incorrectly selected, contact the service and
maintenance engineer for instructions on how to
adjust this. Information on the maintenance frequency
is provided elsewhere in the
manual (14 "Maintenance frequency").

Error conditions

line one: error code comprising a letter and two
digits, followed by the error description;
lines two to four: alternately, a brief explanation of
the error, and a brief action to resolve the error.
CHECK
SENSOR OR DUMMY
CautionThe displayed action to resolve the error
may only be performed by a service and
LOCK OUT ERRORS
When the cause has been removed, these errors
require a reset with the button
appliance can resume operation.
BLOCKING ERRORS
These errors disappear automatically once the
cause of the error has been removed, after which
the appliance resumes operation by itself.
button

Service condition

!!!
WARNING
!!!
MAX. BURNING HOURS:
SERVICE REQUIRED
Note
The message SERVICE REQUIREDis based on
Instruction manual ADMR
gis
before the