Transfer Belt Cleaning Unit Contact Timing Adjustment; Transfer Belt Cleaning Unit Release Timing Adjustment - Toshiba e-STUDIO281c Service Handbook

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO281c:
Table of Contents

Advertisement

* When the value is not within the recommended values, the trailing edge area of the image
may be out of position for the paper length or the density at the trailing edge area of the image
may become lower. Perform the adjustment confirming the image.
→ "100% A" is displayed
→ Press [1] → [FAX] → (A grid pattern is printed out.)
* The larger the adjustment value is, the longer the distance C becomes (approx. 0.5 mm/6
steps).
[D] Transfer belt cleaning unit contact timing adjustment
While pressing [0] and [5] simultaneously, turn the power ON. → (Adjustment Mode)
(1)
(2)
According to the input value for "Adjustment of secondary scanning direction reproduction ratio
(421)", key in the value shown in the following table.
* Be sure to key in the correct value because incorrect value may reduce the cleaning effi-
ciency of the transfer belt.
Adjustment (code)
Adjustment of secondary scanning direction
reproduction ratio (421)
Transfer belt cleaning unit contact timing
adjustment (284)
<Procedure>
(Adjustment Mode) → (Key in the code [284]) → [START]
→ (Key in a value)
→ [ENTER] or [INTERRUPT] (Stored in memory)
[E]

Transfer belt cleaning unit release timing adjustment

This adjustment has to be performed after "Adjustment of secondary scanning direction reproduction
ratio (421)" Acceptable values are 88 to 168. The larger the value is, the later the transfer belt cleaning
unit release timing becomes.
While pressing [0] and [5] simultaneously, turn the power ON. → (Adjustment Mode)
(1)
(2)
According to the input value for "Adjustment of secondary scanning direction reproduction ratio
(421)", key in the value shown in the following table.
* Be sure to key in the correct value because incorrect value may reduce the cleaning effi-
ciency of the transfer belt.
Adjustment (code)
Adjustment of secondary scanning direction
reproduction ratio (421)
Transfer belt cleaning unit release timing
adjustment (285)
<Procedure>
(Adjustment Mode) → (Key in the code [285]) → [START]
→ (Key in a value)
→ [ENTER] or [INTERRUPT] (Stored in memory)
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Input value
110
111-120
121-130
147
143
141
Input value
110
111-120
121-130
147
143
141
3 - 11
131-140
137
131-140
137
e-STUDIO281c/351c/451c
ADJUSTMENT
3