No.
Tx or Rx
##784
[TX]
##785
[TX]
##787
[TX]
##788
[TX]
##789
[TX]
##790
[RX]
##791
[TX/RX]
##792
[RX]
##793
[RX]

5.3.2 New Error Codes and Recovery methods

Those error codes that have been added starting with the products and those error codes for which remedies unique
to the product are offered are shown together with causes and remedies, where applicable.
##341 Maintenance jet waste ink capacity full
Solution: Replace thewaste ink absorber as follows in the error occurs:
(1) Select 3. EEPROM CLEAR under [8] PRINTER TEST in TEST mode, and the select 0.
(2) Check to make sure that no image exist in memory; then, turn off the power, remove the appropriate parts, and
replace the waste ink absorber.
##342 Cleaning absorption waste ink capacity full
Solution: Replace thewaste ink absorber as follows in the error occurs:
(1) Select 3. EEPROM CLEAR under [8] PRINTER TEST in TEST mode, and the select 0.
(2) Check to make sure that no image exist in memory; then, turn off the power, remove the appropriate parts, and
replace the waste ink absorber.
Download Service Manual And Resetter Printer at http://printer1.blogspot.com
Definition
In ECM transmission, ERR was received after transmission of EOR-
EOM
In ECM transmission, no significant signal can be received after
transmission of EOR-EOP, and the allowed number of procedure signal
re-transmissions was exceeded
In ECM transmission, DCN was received after transmission of EOR-
EOP
In ECM transmission, the allowed number of procedure signal re-
transmissions was exceeded or a T5 time-over (60 sec) condition
occurred after transmission of EOR-EOP
In ECM transmission, ERR was received after transmission of EOR-
EOP
In ECM reception, ERR was transmitted after reception of EOR-Q
During an ECM mode procedure, a signal other than a significant signal
was received
In ECM reception, PPS-NULL between partial pages cannot be detected
In ECM reception, no effective frame was detected while signals were
received at high speed, and a time-over condition occurred