TROUBLESHOOTING GUIDE (continued)
LED PANEL
CODE
LED Panel Code Flash & Alarm On (NOTE: Always turn off the power before cleaning and servicing).
1. Circulation line is blocked.
2. Incorrect inlet and outlet hose
direction.
3. Scale on the flow sensor.
4. Flow sensor cord is loose.
5. Device is set and operating in
backwash, rinse or waste mode.
6. Flow sensor failure.
1. Dirt or scale on titanium plates.
2. Low salt level / No salt.
3. Electrolytic cell cord is loose.
4. Possible electrolytic cell failure.
1. High salt level.
2. Possible electrolytic cell failure.
1. Display and all lights are off - the
system does not power up.
SAVE THESE INSTRUCTIONS
(261PO) Sand Filter Pump & Saltwater System with E.C.O. ENGLISH 7.5" X 10.3" PANTONE 295U 07/23/2014
PROBLEM
SOLUTION
• If your unit has plunger valves, ensure
that they are open.
• Clear your basket and cell from
debris and dirt. See "Maintenance".
• Depress the 6-way valve, release all
trapped air in the circulation line.
• Check the direction of the inlet and the
outlet hose. Reverse the hoses if
necessary. See "Set Up Instructions".
• Clean the flow sensor, paying special
attention to the hinge. See
"Maintenance".
• Plug the flow sensor firmly into the flow
sensor receptacle.
• Ignore the alarm, finish the backwash, rinse
or waste operation then turn the power
switch OFF and ON again to reset the alarm.
• Contact Intex Service Center.
• Remove the electrolytic cell for
inspection. Clean it if necessary.
See "Maintenance".
• Add salt. See "Salt & Pool Water
Volumes".
• Ensure that the cell cord is plugged
firmly into the cell housing receptacle.
• Contact Intex Service Center. Replace
the cell if needed.
• Partially drain the pool and refill it with
fresh water. See "Salt & Pool Water
Volumes".
• Contact Intex Service Center. Replace
the cell if needed.
• Household voltage is too high or too low
(+ 20%). Check the voltage is within the
range stated on the device housing.
• Contact Intex Service Center.
261