Intex CS20110 Owner's Manual

Intex CS20110 Owner's Manual

Krystal clear sand filter pump & saltwater system
Hide thumbs Also See for CS20110:

Advertisement

2015-6332
2016-02-12
EN
Reg. No. 30116 P.C.P.A
KRYSTAL CLEAR
SAND FILTER PUMP
TM
& SALTWATER SYSTEM
MODEL CS20110
110 – 120 V~, 60 Hz, 7.1 A (0.95HP) THERMALLY
PROTECTED, WEATHERPROOF ENCLOSURE, CSA
ENCLOSURE 3, FOR USE WITH SWIMMING POOLS ONLY.
WARNING
A
GROUNDING
RISK OF ELECTRIC SHOCK. CONNECT ONLY TO
TYPE RECEPTACLE PROTECTED BY A CLASS A GROUND FAULT
CIRCUIT INTERRUPTER (GFCI).
CAUTION
TO ENSURE CONTINUED PROTECTION AGAINST SHOCK HAZARD,
USE ONLY IDENTICAL REPLACEMENT PARTS
WHEN SERVICING. THIS PRODUCT IS FOR USE WITH
STORABLE POOLS ONLY, DO NOT USE WITH PERMANENTLY
INSTALLED POOLS.

Advertisement

Table of Contents
loading

Summary of Contents for Intex CS20110

  • Page 1 2015-6332 2016-02-12 Reg. No. 30116 P.C.P.A KRYSTAL CLEAR SAND FILTER PUMP & SALTWATER SYSTEM MODEL CS20110 110 – 120 V~, 60 Hz, 7.1 A (0.95HP) THERMALLY PROTECTED, WEATHERPROOF ENCLOSURE, CSA ENCLOSURE 3, FOR USE WITH SWIMMING POOLS ONLY. WARNING GROUNDING RISK OF ELECTRIC SHOCK.
  • Page 2 Reg. No. 30116 P.C .P.A. WARNING – RISK OF ELECTROCUTION CONNECT ONLY TO PROPERLY GROUNDED OUTLET. DO NOT REMOVE GROUNDING PIN. INSPECT CORD BEFORE USING – DO NOT USE IF CORD IS DAMAGED. KEEP GROUND-FAULT CIRCUIT-INTERRUPTER DRY AND OFF THE GROUND. DO NOT TOUCH PLUG WITH WET HANDS.
  • Page 3 WARNING: Operating Krystal Clear™ SAND Filter Pump & Saltwater System Model CS20110 without water flow through the cell can cause a build up of flammable gases which can result in FIRE OR EXPLOSION. Staining of pool surfaces may occur due to deposits of copper salts.
  • Page 4 This cell must only be used on these models of Krystal Clear™ Sand Filter Pump & Saltwater System. Read the Label, the Installation Manual and Operation Manual of the Krystal Clear™ Sand Filter Pump & Saltwater System Model CS15110 and Model CS20110 before using. REGISTRATION NOS. 30115 and 30116 PEST CONTROL PRODUCTS ACT.
  • Page 5 Read the Label, the Installation Manual and Operation Manual of the copper ionization device Krystal Clear Saltwater System Model CS20110 before using. Registrant: Intex Trading Ltd., 9th floor Dah Sing Financial Center, 108 Gloucester Road, Wanchai, Hong Kong Canadian Agent: The Canadian Group, 430 Signet Drive Suite A, Toronto, Ontario M9L2T6,...
  • Page 6 REGISTRATION NO. 30116 PEST CONTROL PRODUCTS ACT 410mm (16") For illustrative purposes only. Don’t forget to try these other fine Intex products: pools, pool accessories, inflatable pools and in-home toys, airbeds and boats available at fine retailers or visit our website. IMPORTANT!
  • Page 7: Table Of Contents

    Operating Instructions ..........18-22 LED Code Chart.............. 23 Intex Pools Salt Table............24 Intex Pools Operating Time Table ......... Intex Pools Cyanuric Acid Table........Non-Intex Pools Salt Table..........27 Non-Intex Pools Operating Time Table......Non-Intex Pools Cyanuric Acid Table......27 Maintenance..............
  • Page 8: Warnings

    Please use common sense and good judgment when enjoying any water activity. Follow all aspects of the local and National Electrical Code(s) when installing Krystal Clear Sand Filter Pump and Saltwater System Model CS20110. SAVE THESE INSTRUCTIONS...
  • Page 9 KEEP OUT OF REACH OF CHILDREN. REGISTRATION NO. 30116 PEST CONTROL PRODUCTS ACT. Registrant: Intex Trading Ltd., 9th floor Dah Sing Financial Center, 108 Gloucester Road, Wanchai, Hong Kong Canadian Agent: The Canadian Group, 430 Signet Drive Suite A, Toronto, Ontario M9L2T6,...
  • Page 10: Parts List & References

    English PARTS LIST NOTE: Drawings for illustration purpose only. Actual product may vary. Not to scale. SAVE THESE INSTRUCTIONS Page 5...
  • Page 11 English PARTS LIST (continued) NOTE: Drawings for illustration purpose only. Actual product may vary. Not to scale. SAVE THESE INSTRUCTIONS...
  • Page 12 PARTS REFERENCE Before assembling your product, please take a few minutes to check the contents and become familiar with all the parts. NOTE: Drawings for illustration purpose only. Actual product may vary. Not to scale. SAVE THESE INSTRUCTIONS...
  • Page 13 PARTS REFERENCE (continued) Before assembling your product, please take a few minutes to check the contents and become familiar with all the parts. NOTE: Drawings for illustration purpose only. Actual product may vary. Not to scale. SAVE THESE INSTRUCTIONS...
  • Page 14 PARTS REFERENCE (continued) Before assembling your product, please take a few minutes to check the contents and become familiar with all the parts. DESCRIPTION QTY. REF. NO. SPARE PART NO. 11321 6-WAY VALVE SET 11224 PRESSURE GAUGE 11131 DRAIN OUTLET COVER CENTER PIPE HUB 11268 TANK O-RING...
  • Page 15 English POOL OUTLET - STRAINER & PLUNGER VALVE SETUP The strainer grid prevents large objects from jamming and/or damaging the filter pump. If your pool has an inflatable top ring, install the strainer, nozzle and plunger valve before inflating the pool liner top ring. The part numbers here onward refer to the parts depicted in the Parts List section of this manual.
  • Page 16 POOL INLET - NOZZLE & PLUNGER VALVE SETUP 1. In a counter-clockwise motion unscrew plunger valve union from the threaded strainer connector (31) (see drawing 5). Be careful not to lose the step rubber washer (28). Place the plunger valve on the ground in a safe place.
  • Page 17: Setup Instructions

    English PRODUCT SPECIFICATIONS The sand filter removes suspended particles from your pool. Pool chemistry is a specialized area and you should consult your local pool service specialist for details. Power: 110 - 120 Volt AC Amperage: Saltwater System - 1.1 A; Filter Pump - 6 A Wattage: Saltwater System - 120 W;...
  • Page 18 English SETUP INSTRUCTIONS (continued) 4. In a clockwise motion screw filter housing nut (20) onto the motor water inlet (See drawings 12.1 & 12.2). 5. Replace the basket (19) and leaf trap cover (17) back to the pre-filter housing (See drawings 13.1 & 13.2). Sand tank installation: Place the tank on the selected location.
  • Page 19 SETUP INSTRUCTIONS (continued) 3. In a clockwise motion screw the center pipe (4) onto the filter grid (6) securely by hand (see drawing 15). 4. Vertically insert the filter grid and center pipe assembly into the tank. Ensure filter grid assembly is securely fitted to the bottom of the tank, and the center pipe is vertically centered inside the tank (see drawing 16).
  • Page 20 SETUP INSTRUCTIONS (continued) Sand shall be filled between the “MAX” and “MIN” marked gauge on the center pipe. Evenly spread and level out the sand by hand (see drawings 19 & 20). Remove the protective cup from the center pipe top opening. Wash away all sand around the top edge of the tank.
  • Page 21 SETUP INSTRUCTIONS (continued) Remove the clamp bolt cover and the clamp bolt (13), and install the flange clamp around the tank and 6-way valve flanges (see drawing 24). Insert the clamp bolt (13) into the pre-installed nut on the clamp, and securely tighten it with the wrench (14) supplied.
  • Page 22 SAND FILTER PUMP HOSE CONNECTION SETUP WARNING • Keep this product more than 2m away from the pool. • Keep this product more than 3.5m away from the pool (for France only). • Keep the plug of this product more than 3.5m away from the pool. •...
  • Page 23 Tighten securely. Remove the drain cap (3) before attaching the drain/waste hose or pipe. For INTEX pool size 4.88 m (16') and below: 1. In a counter-clockwise motion unscrew plunger valve union from the threaded strainer connector (31). Be careful not to lose the step rubber washer (28).
  • Page 24: Operating Instructions

    OPERATING INSTRUCTIONS WARNING • Risk of electric shock. Connect this product only to a grounding type receptacle protected by a ground-fault circuit interrupter (GFCI) or residual current device (RCD). Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI/RCD. Use a qualified electrician to install the GFCI/RCD, which has a maximum rate of 30mA.
  • Page 25 OPERATING INSTRUCTIONS (continued) Initial startup and operation: Before operating, be sure that: • All the hoses have been connected and tightened securely, and correct amount of filter sand has been loaded. • The entire system is connected to a grounding type receptacle protected by a ground-fault circuit interrupter (GFCI) or residual current device (RCD).
  • Page 26 “BACKWASH” under “initial startup and operation” section. Vacuuming devices (i.e. Intex auto pool cleaner) attached to the system may also cause the flow to diminish and the pressure to rise. Remove any vacuuming device from the system and check if the pressure gauge reading has dropped from the yellow zone to the green zone.
  • Page 27 SALTWATER SYSTEM OPERATION 1. Start up the unit: Plug the power cord into the electrical outlet and test the GFCI/RCD (circuit breaker). Switch on the unit. With the Filter Pump turned “ON” and operating, the green "Pump" light on the control panel will be on and code “00”...
  • Page 28 SALTWATER SYSTEM OPERATION (continued) 7. Boost cycle If the test result is below 0.2 ppm, press and hold “BOOST” button for 5 • seconds until the indicator lights up and the LED display displays “80”. This indicates that the saltwater system has started copper ion production. You can press and hold the “BOOST”...
  • Page 29: Led Code Chart

    • When replacing the chlorine generating cell and copper cell, only use replacement cells having a label that clearly states that it is a replacement cell for the Krystal Clear Sand Filter Pump and Saltwater System Model CS20110 REGISTRATION NUMBER 30116, PEST CONTROL PRODUCTS ACT.
  • Page 30: Intex Pools Salt Table

    INTEX POOLS SALT TABLE This table shows the dosage of salt needed to achieve and maintain the optimal 3000 ppm salt level. Salt Needed for Salt Needed when Water Capacity (Calculated at 90% for Frame Pool and 80% Startup Low Salt Detected Pool Size for Easy Set &...
  • Page 31: Intex Pools Operating Time Table

    INTEX POOLS OPERATING TIME TABLE (WITH CYANURIC ACID) Operating Time (hours) Water Capacity (Calculated at at different ambient/air 90% for Frame Pool and 80% for temperatures Easy Set & Oval Pool) Pool Size 10 - 19°C 20 - 28°C 29 - 36°C...
  • Page 32: Intex Pools Cyanuric Acid Table

    INTEX POOLS CYANURIC ACID TABLE Cyanuric acid is a chemical that reduces the loss of chlorine in water due to ultraviolet rays. To maintain maximum performance, we recommend that the cyanuric acid level be maintained between 30-100 ppm. Cyanuric Acid Needed for...
  • Page 33: Non-Intex Pools Salt Table

    8000 30000 10000 37500 12000 45500 14000 53000 OPERATING TIME TABLE FOR COMMON NON-INTEX POOLS (WITHOUT CYANURIC ACID Operating Time (hours) Water Capacity at different ambient/air temperatures 10 - 19°C 20 - 28 °C 29 - 36 °C (Gals) (Liters) (50 - 66°F)
  • Page 34: Maintenance

    MOTOR PRE-FILTER CLEANING AND MAINTENANCE 1. Make sure the filter pump is switched off, then disconnect the power cord from the electrical outlet. 2. Grasp a plunger valve handle. Turn the handle counter-clockwise, push down until it stops and then turn it clockwise until the plastic protruding notch anchors in the "0/1"...
  • Page 35 COPPER ELECTRODE CLEANING 1. Switch off the unit, unplug the power cord from the electrical socket. 2. In a counter-clockwise motion, unscrew the electrical plug collar from the copper electrode cell, and remove the electrical plug from electrode cell (see drawings 44 and 45).
  • Page 36: Long Term Storage

    LONG TERM STORAGE & WINTERIZATION CAUTION Allowing the water to freeze will damage the sand filter and void the warranty. If anti-freeze solution is needed, use only propylene glycol. Propylene glycol is non-toxic and will not damage plastic system components; other anti-freezes are highly toxic and may damage plastic components in the system.
  • Page 37: Troubleshooting Guide

    • Excessively dirty pool. • Set valve to “ FILTER” position. • Dirt or sand on pool floor. • Operate the filter for longer periods. • Use Intex pool vacuum to clean bottom • The basket is restricting the water flow. of pool.
  • Page 38 Volumes”. • Ensure that the cell cord is plugged 3. Electrolytic cell cord is loose. firmly into the cell housing receptacle. • Contact Intex Service Center. Replace 4. Possible electrolytic cell failure. the cell if needed. 1. High salt level.
  • Page 39: Common Pool Problems

    • Finger tighten all caps. LEVEL • The drain valves are loose. SEDIMENT • Dirt or sand on • Heavy use, getting in • Use Intex pool vacuum to ON POOL pool floor. and out of pool. clean bottom of pool. BOTTOM SURFACE •...
  • Page 40: General Aquatic Safety

    GENERAL AQUATIC SAFETY Water recreation is both fun and therapeutic. However, it involves inherent risks of injury and death. To reduce your risk of injury, read and follow all product, package and package insert warnings and instructions. Remember, however, that product warnings, instructions and safety guidelines cover some common risks of water recreation, but do not cover all risks and dangers.
  • Page 41: Limited Warranty

    This Limited Warranty applies only to those parts and components sold by Intex. The Limited Warranty does not cover unauthorized alterations, repairs or disassembly by anyone other than Intex Service Center personnel.
  • Page 42: Intex Service Center Locations

    COUNTRIES/REGIONS SERVICE CENTER LOCATIONS • UNITED STATES INTEX RECREATION CORP. 14779 Bar Harbor Road • CANADA Fontana, CA 92336 Tel: 1-800-234-6839 Fax: 310-549-2900 Website: www.intexcorp.com (U.S./Canada only) Consumer Service Hours: 8:30 am to 5:00 pm Pacific Time, Mon. thru F .
  • Page 43 Monday thru Friday only Website: www.intexcorp.com For Residents outside of the U.S. and Canada: Please refer to the Service Center Locations Intex Marketing Ltd. - Intex Trading Ltd. - Intex Trading ©2011 Ltd. - Intex Recreation Corp. All rights reserved/Tous droits réservés/Todos los derechos reservados/Alle Rechte vorbehalten.
  • Page 44 ****************************** This label transcript service is offered by the Pest Management Regulatory Agency to provide efficient searching for label information. This service and this information do not replace the official hard-copy label. The PMRA does not provide any guarantee or assurance that the information obtained through this service is accurate, current or correct, and is therefore not liable for any loss resulting, directly or indirectly, from reliance upon this service.