Intex ECO 20110 Owner's Manual page 31

Sand filter pump & saltwater system with e.c.o. (electrocatalytic oxidation)
Table of Contents

Advertisement

TROUBLESHOOTING GUIDE (continued)
PROBLEM
• Without cyanuric acid.
INSUFFICIENT
• Insufficient operating hours of
CHLORINE
the Saltwater System.
• The salt level in the pool water
• Chlorine loss due to intense
• The bather load has increased.
• Clogged or dirty electrolytic cell.
• High UV level exposure.
• Excessive calcium hardness is
WHITE FLAKES IN
THE WATER
• No power supply.
NO LED DISPLAY
• RCD/GFCI has not reseted.
• A power fuse has blown.
• LED failure.
SAVE THESE INSTRUCTIONS
(261PO) Sand Filter Pump & Saltwater System with E.C.O. ENGLISH 7.5" X 10.3" PANTONE 295U 07/23/2014
CAUSE
is less than 2000ppm. This is
insufficient.
sunlight exposure.
present in pool water.
SOLUTION
• See "Cyanuric acid table".
• Increase the daily Saltwater System
operating time. See "Operating Instructions".
• Check the salt level with the Test Kit.
Adjust as needed. See "Salt & Pool Water
Volumes".
• Use a pool cover when the pool is not in use
and/or when the unit is operating.
• Increase the daily Saltwater System
operating time. See "Operating Instructions".
• Remove the cell for inspection, clean it if
necessary. See "Maintenance".
• Cover the pool with a pool cover for 2 days
with the device running and then test the
waterusing the test strips.
• If the pool is clean and clear, add stabilizer
to the water and then test the water.
• Drain about 20 to 25% of the pool
water and add fresh water to decrease
the calcium hardness. Inspect the
electrolytic cell for scale buildup. Clean
the electrolytic cell if necessary.
• Plug the cell cord firmly into the cell
housing receptacle.
• Reset the RCD/GFCI.
• Contact Intex Service Center.
• Contact Intex Service Center.