■ Potential Sensor

Procedure of parts
Refer to Chapter 0, "After Removing the ITB Cleaning Blade Unit."
replacement
Procedure of
1) Install the Primary Charging Rail, which is in the condition of removing the
adjustment
Electric Potential Sensor, to the main unit.
• 1 screw
Primary Charging Rail
NOTE:
Put the Primary Charging Rail at the angle shown in the figure, and
insert 2 bosses in the boss holes on the main unit.
Screw
Procedure of
2) Install the ITB Unit to the main unit.
adjustment
NOTE:
Purpose to remove the ITB Unit in this procedure is to prevent the
ITB from a damage caused by dropping a part.
3) Connect a new cable to the connector on new electric potential sensor.
4) Install the electric potential sensor by aligning with the boss [A] of the
electrode for the potential sensor check
• 1 connector
• 1 screw
Caution:
Be sure to tighten the screw to prevent the Potential Sensor
coming off.
F-2-1
T-2-22
Electric Potential Sensor
[A]
[A]
Connector
Screw
2
T-2-23