Download Print this page

Technical Data; Operating Conditions; Performance Data - Dimplex AWP 30 HLW Installation And Operating Instructions Manual

Hot water heat pump for indoor installation

Advertisement

Available languages

Available languages

12 Technical Data

1
Type and order code
2
Design
2.1
Casing
2.2
Colour
2.3
Nominal cylinder volume
2.4
Cylinder material
2.5
Nominal cylinder pressure
3
Model
3.1
Dimensions W x H x D (overall)
3.2
Weight
3.3
Electrical connection (plug-in - lead length approx. 2.7 m)
3.4
Fuse
3.5
Refrigerant / total filling weight
4

Operating conditions

4.1
Selectable water temperature (heat pump operation
4.2
Air temperature operating range of heat pumps
2
4.3
Sound pressure level
4.4
Air flow during heating-only heat pump operation
4.5
External compression
4.6
Maximum length of pipe that can be used for the air duct m
5
Connections
5.1
Diameter of the air duct connection (inlet/outlet)
5.2
Transfer area of the internal tube heat exchanger
5.3
Sensor pipe D internal
(for sensor – heat exchanger operation)
5.4
Water connections - cold water / hot water
5.5
Circulation pipe
5.6
Heat exchanger flow / return flow
6

Performance data

3
6.1
Mean power consumption
4
6.2
Mean heat output
at 45 °C
6.3
COP (t) according to EN 255 at 45 °C
6.4
Stand-by energy consumption at 45 °C/24h
6.5
Max. mixed water volume at 40 °C
6.6
Heating-up period from 15 °C to 60 °Ct h
1. At temperatures below 8 °C (+/- 1.5 °C) the heating element switches on automatically and the heat pump module switches off automatically; the switch-back value of the controller
is 3 K
2. At a distance of 1 m (free-standing installation without inlet and outlet ducting or without 90° pipe bends on the outlet side)
3. Heating up of the nominal volume from 15 °C to 60 °C at an air inlet temperature of 15 °C and 70 % relat. humidity
4. Heating up of the nominal volume from 15 °C to 45 °C at an air inlet temperature of 15 °C and 70 % relat. humidity
www.dimplex.de
l
bar
mm
kg
A
- / kg
±1.5 K
) °C
1
°C
dB(A)
3
m
/h
Pa
mm
2
m
mm
at 60 °C
W
W
-
(W)
V max.
l
h
AWP 30HLW
with additional internal heat exchanger
Painted sheet steel
White, similar to RAL 9003
290
Enamelled steel according to DIN 4753
10
660 x 700 x 1700
Approx. 175
1/N/PE ~ 230 V, 50 Hz
16
R134a / 1.0
23 to 60
8 to 35
53
450
100
10
160
1.45
12
R 1"
R 3/4"
R 1"
615
1870
3.5
47
290
9.1
12
E-11

Advertisement

loading

This manual is also suitable for:

Awp 30 hlw