HELP32
Anti-diffusion agent (A-20): J-6082-611-A
Apply the anti-diffusion agent (A-20) to the shaded area. Avoid applying anti-diffusion agent (A-20) to the inside wall of the barrel.
Apply the anti-diffusion agent (A-20)
A
A - A
HELP33
Anti-diffusion agent (A-20): J-6082-611-A
Grease (G-115):
Grease (G-15):
Adhesive bond (B-40):
1.
Apply the anti-diffusion agent (A-20) to the instruction part of the middle barrel as shown in the figure.
2.
Apply the grease (G-115) to the guide groove of the middle barrel at three points.
3.
Apply the grease (G-15) to the groove of the cam plate, apply the Adhesive bond (B-40) to the two screws and install the cam plate.
Apply the anti-diffusion agent
(A-20) (All circumference)
SAL50M28 (MACRO 2.8/50) (50mm F2.8 Macro)
A
J-6082-627-A
J-6082-619-A
J-6082-614-A
Apply the adhesive
bond (B-40)
Apply the grease (G-15)
(Guide groove portion)
Apply the grease (G-115)
(Guide groove at three points and groove portion)